Step 10
Check that all burner valves are off
You will need: one burner control knob.
(Valves are shipped in the OFF position, but you should
check to be sure.) Put the knob on each valve. Check by
pushing down and turning clockwise. Figure 11.
Figure 11
Step 11
Connect flexible hose to manifold
You will need: the 12 foot gas supply hose and a 3/4
inch wrench.
Thread fitting end of hose onto manifold. Figure 12 (a).
Tighten with wrench.
Figure 12
(a)
Step 12
Install igniter
Note - The igniter wires are already attached to the Gas
Catcher Ignition Chamber and the igniter. This was done
to factory test the ignition system.
The igniter lock nut is on the igniter.
Insert the top of the igniter up through the large part of the
keyhole in the frame brace. Loosen the igniter lock nut
and slide the igniter to the rear of the keyhole. Tighten the
igniter lock nut. Figure 13.
Note - If the igniter works loose, carefully tighten the
igniter lock nut with an adjustable wrench or pliers.
Figure 13
Keyhole in
frame brace
Igniter lock nut
14