EXHAUSTING THE DRYER (cont.)
SIDE VENTING (cont.)
ADDING COVER PLATE TO REAR OF CABINET
(SIDE EXHAUST)
Cover Plate
Connect standard metal elbows and ducts to
complete the exhaust system. Cover back opening
with a cover plate (Cover Plate – WE1M545)
available from your local service provider. Place
dryer in final location.
WARNING –
THE BACK OPENING WITHOUT THE PLATE.
COVER BACK OPENING WITH A COVER PLATE
(COVER PLATE – WE1M545) AVAILABLE FROM
YOUR LOCAL SERVICE PROVIDER.
Installation Instructions
NEVER LEAVE
BOTTOM VENTING:
Dryer Exhaust to the bottom of cabinet
WARNING –
THIS EXHAUST INSTALLATION, BE SURE TO
DISCONNECT THE DRYER FROM ITS ELECTRICAL
SUPPLY. PROTECT YOUR HANDS AND ARMS
FROM SHARP EDGES WHEN WORKING INSIDE
THE CABINET. BE SURE TO WEAR GLOVES.
Remove
screw
and save
Remove the screw inside the dryer exhaust duct
and save. Pull the duct out of the dryer. Detach
and remove the bottom knockout.
Cut the duct as shown and keep portion A.
22
BEFORE PERFORMING
Bottom
Remove desired
knockout (one only)
Fixing hole
A
4.9" (125 mm)