OSD Menu
Parking Action Setup
PARKING ACTION SETUP
------------------------
PARK ENABLE
WAIT TIME
PARK ACTION
BACK
EXIT
38
This feature allows the camera to begin a specified action after a
programmed time of inactivity.
OFF
00:10:00
Park Enable
HOME
Wait Time
Park Action
[ON/OFF]
If Park Enable is set to ON, the camera runs an
assigned function automatically if no PTZ command is
received during the programmed Wait Time.
[1~59 sec. / 1~180 min.]
Wait Time can be programmed from 1 second to 180
minutes.
[HOME/PRESET/PATTERN/SWING/GROUP/PREV
ACTION]
This feature defines the activity when the camera
parks. If Park Action is set to HOME, the camera
moves to the home position which is memorized when
the system boots. If Park Action is set to PREV.
ACTION, the camera runs the most recent action.