MENU Screen Functions
Press MENU to bring up MENU screen.
TIME of DAY
Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per
touch). Touch and hold the arrow for fast time set (15 minute jumps).
SWING
(HVAC cycling rate) This feature allows you to set the desired variance in temperature
between the CT101 setting and the room temperature required before the heating or cooling system
will turn on—Swing range: 0.5 to 4.0F (.25 to 2C). For example, if SWING is set to 2.0° F and the
CT101 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to
68°F. Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC
then runs and will shut off at the Target Temperature.
To set SWING:
Touch SWING.
Touch the left/right arrows to set the SWING from 0.5° to 2.0°F.
The HVAC will run more frequently at .5°F and less at 2°F. Default is 1°F.
Touch
to return to the MENU screen.
Chirp set
Touch this to turn the audible chirp sound on or off.
-