Troubleshooting Guide Continued - Kenmore 153.331762 Use & Care Manual

74 gallon (280 liter)
Table of Contents

Advertisement

TROUBlESHOOTING GUIDE CONTINUED

Problem
Improperly sealed, hot or cold supply connection,
relief valve, drain valve, or thermostat threads.
wATER lEAKS
Leakage from other appliances or water lines.
Condensation of flue products.
Thermal expansion in closed water system.
lEAKING T&P VAlVE
Improperly seated valve.
High sulfate or mineral content in water supply.
SMEllY ODORS
Bacteria in water supply.
Gas control knob not positioned correctly.
Main gas supply off.
PIlOT wIll NOT lIGHT
Thermocouple malfunction.
Thermocouple malfunction.
BURNER wIll NOT
STAY lIT
Defective Gas Control.
Dirty pilot burner.
Thermocouple malfunction.
Thermocouple tip is not in contact with pilot flame.
PIlOT OUTAGE
Defective Gas Control.
Heater not lit or thermostat not on.
Thermostat set too low.
Heater undersized.
NOT ENOUGH
Low gas pressure.
HOT wATER
Incoming water is unusually cold.
Leaking hot water pipes or fixtures.
High temperature limit switch activated.
Thermostat set too high.
wATER TOO HOT
wATER HEATER SOUNDS
Condensation dripping on burner.
Sediment or calcium in bottom of heater tank.
SIZZlING OR
RUMBlING
Improper combustion.
SOOTING
Lack of supply air.
Improperly installed vent piping.
VENT GAS ODORS
Downdraft.
Poor combustion.
These guidelines should be used by a qualified service agent. Call Sears Service
at 1-800-4-MY-HOME
Cause
(1-800-469-4663) for assistance.
®
Tighten threaded connections.
Inspect other appliances near water heater.
Refer to CONDENSATION.
Install thermal expansion tank (DO NOT plug T&P valve).
Check relief valve for proper operation
(DO NOT plug T&P valve).
Drain and flush heater thoroughly, then refill.
Chlorinate or aerate water supply.
Refer to LIGHTING INSTRUCTIONS.
Turn on main gas shutoff valve.
Replace pilot assembly and/or thermocouple.
Replace pilot assembly and/or thermocouple.
Replace Gas Control.
Clean pilot assembly.
Replace pilot assembly and/or thermocouple.
Insert thermocouple correctly.
Replace Gas Control.
Refer to LIGHTING INSTRUCTIONS.
Refer to TEMPERATURE REGULATION.
Reduce hot water use.
Contact your gas supplier.
Allow more time for heater to re-heat.
Have plumber check and repair leaks.
Contact Sears Service to determine cause.
Refer to TEMPERATURE REGULATION.
Refer to CONDENSATION.
Clean sediment from tank. Refer to DRAINING
instructions in Maintenance section of manual.
No adjustment available. Contact Sears Service
to determine cause.
Contact Sears Service to determine cause.
28
Solution

Hide quick links:

Advertisement

Table of Contents
loading