Troubleshooting Guide; Start Up Conditions; Thermal Expansion; Strange Sounds - Kenmore POWER MISER 9 Owner's Manual

For potable water heating only not suitable for space heating
Hide thumbs Also See for POWER MISER 9:
Table of Contents

Advertisement

Troubleshooting Guide

Start Up Conditions

THERMAL EXPANSION

Water supply systems may, because of such events as high line
pressure, frequent cut-offs, the effects of water hammer among
others, have installed devices such as pressure reducing valves,
check valves, back flow preventers, etc...to control these types of
problems. When these devices are not equipped with an internal
by-pass, and no other measures are taken, the devices cause the
water system to be closed. As water is heated, it expands (ther-
mal expansion) and closed systems do not allow for the expan-
sion of heated water.
The water within the water heater tank expands as it is heated and
increases the pressure of the water system. If the relieving point of
the water heater's temperature-pressure relief valve is reached, the
valve will relieve the excess pressure. The temperature-pressure
relief valve is not intended for the constant relief of thermal
expansion. This is an unacceptable condition and must be cor-
rected.
It is recommended that any devices installed which could create a
closed system have a by-pass and/or the system have an expan-
sion tank to relieve the pressure built by thermal expansion.
Thermal expansion tanks are available from Sears stores and
through the Sears Service Centers. Contact the local plumbing
inspector, water supplier and/or the Sears Service Center for
assistance in controlling these situations.
Thermal Expansion Tank Specifications
Model
Tank Capacity Dimensions in Inches Pipe Fitting
Number
In Gallons
153.331020
2
153.331050
5
Expansion Tank Sizing Chart
Inlet*
Water
Pressure
Expansion
40psi
Tank
50psi
Capacity
Needed
60psi
70psi
80psi
*Highest recorded inlet water pressure in a 24 hour period or
regulated water pressure.
NOTE: Expansion tanks are pre-charged with a 40 psi air
charge. If the inlet water pressure is higher than 40 psi, the
expansion tank's air pressure must be adjusted to match that
pressure, but must not be higher than 80 psi.
Diameter
Length
8 inches 12
3
inches
4
11 inches 14
3
inches
4
Water Heater Capacity (Gallons)
30
40
50
66
2
2
2
5
2
2
2
5
2
2
5
5
2
2
5
5
2
5
5
5
HOT
WATER HEATER
COLD WATER
INLET FITTING
HOT
On Tank
" Male
3
4
" Male
3
4
80
5
5
5
5

STRANGE SOUNDS

5
Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not represent
harmful or dangerous conditions.
21
WATER HEATER
COLD
COLD WATER
INLET FITTING
(1)
EXPANSION
TANK
(2)
PRESSURE GAUGE
RECOMMENDED INSTALLATION
(VERTICAL MOUNTING)
FLOOR, CEILING
JOIST, ETC.
COLD
STRAPPING
PRESSURE
REDUCING
VALVE WITH
BY-PASS
(1)
EXPANSION
TANK
(2)
PRESSURE GAUGE
ALTERNATE RECOMMENDED
INSTALLATION
(HORIZONTAL MOUNTING)
(3)
PRESSURE
REDUCING
VALVE WITH
BY-PASS
INLET COLD
WATER
SHUTOFF
(3)
INLET COLD
WATER
SHUTOFF