Download Print this page

Carrier 53DFST2-NP Owner's Manual page 4

Programmable digital thermostat

Advertisement

Advanced Setup
IMPORTANT: Be sure to press and hold the override button
with the Mode button for full ten seconds.
NOTE: Step 5 is not applicable for use with Duct-Free Split Heat Pump
Systems.
Press the Mode button. While holding the Mode, press the Override button to
eave the Setup screens. If no buttons are pressed, the display will leave the
setup screens after 60 seconds.
:
Pm
Setup
Su
Setup
Setup
ON
Setup
Setup
OFF
Setup
Setup
Setup
Setup
ON
Setup
Advanced Setup Table
STEP NO.
DESCRIPTION
1
Time of day clock set
2
Day of the week
3
Display Blanking
4
Fan Operation
5
Heat Pump*
6
Deadband or Temperature swing
Forced minimum difference
7
heat/cool
8
Cycles per hour
9
Thermoglow™ backlight
10
Fahrenheit or Celsius
*Not applicable for use with Duct-Free Split Heat Pump systems.
About Advanced Features and Operation
• CLOCK BACKUP — In the event of a power loss,
the thermostat internal clock will continue to keep
proper time for a minimum of 48 hours without
external power or batteries.
• MINIMUM HEAT/COOL SETPOINT DIFFERENCE
— The Heat and Cool set points will not be allowed
to come any closer to each other than the value set
in Advanced Setup Step 6, on this page . This mini-
mum difference is enforced during Auto changeover
and Program On operation.
• ENERGY SAVING SMART FAN — If a manual fan
speed is selected, the fan will run continuously at all
times. If mode is Off, the fan will only run if there is a
heating or cooling demand in Unoccupied periods.
• OVERRIDE — As explained on page 2 , pressing
the Override button during a programmed, Unoccu-
pied period will force the thermostat into Occupied
1, temporarily, for up to 4 hours. If the Override but-
ton is pressed during an Occupied period, the ther-
mostat will be forced into Unoccupied and the
occupied period (1,2 or 3) , it was forced out of will
be turned off, only for that day.
During Override periods the set points may be
adjusted, but they will not be remembered after
Override ends.
• KEYPAD LOCK — To prevent unauthorized use of
the thermostat, the front panel buttons may be dis-
abled. To disable or 'lock' the keypad, press and
hold the Mode button. While holding the Mode but-
ton, simultaneously press the Up and Down but-
tons. The Locked icon will appear on the display.
To unlock the buttons, again press and hold the
Mode button. While holding the Mode button, simul-
taneously press the Up and Down buttons. Locked
will disappear from the display.
• DISPLAY BLANKING — The thermostat display
may be configured in advanced setup, this page,
Step 3, to always be visible as normally expected,
or may be selected Off. When selected Off, only the
time of day will appear until a button is pressed.
When a button is pressed the full, normal display
will appear and then revert to the time of day only,
after roughly 10 seconds.
Page 4
FACTORY
RANGE
DEFAULT
24 hour
12:00 Am
Su - Sa
Mo
Off / On
On
Auto / On
Auto
Off / On
On
1 - 6 F
2 F
0 - 6 F
2 F
d, d1, 2 - 6
6
Off / On
On
F / C
F
:
Pm
Mo
Cool
unoccupied
Locked
o
Heat
ProgramOn