Electrical Adjustments
1 2 1 1 x
Pedestal adjustment
1. Receive the 16-step grey scale video signal.
2. Set to VIDEO mode.
3. Enter the service mode.
4. Connect an oscilloscope to test point "
and chassis ground (-).
3
5. Select group no. "
", item no. "
value to adjust the pedestal level and black level to be
the same level.
6. Connect an oscilloscope to test point "
and chassis ground (-).
3
7. Select group no. "
", item no. "
value to adjust the pedestal level and black level to be
the same level.
8. Connect an oscilloscope to test point "
and chassis ground (-).
3
9. Select group no. "
", item no. "
value to adjust the pedestal level and black level to be
the same level.
Pedestal level = Black level
1 2 1 c
NRS adjustment
1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Connect an oscilloscope to test point "TP3551" (+)
and chassis ground (-).
4. Enter the service mode, select group no. "
7
"
" and change data value to adjust amplitude "a" to
5.5
be
±0.1V.
(a)
TP201R
" (+)
14
" and change data
TP201G
" (+)
15
" and change data
TP201B
" (+)
16
" and change data
(a)
3
", item no.
-27-
1 2 1 v
Signal Center adjustment
1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
4. Connect a digital voltmeter to test point "
and chassis ground (-).
3
5. Select group no. "
", item no. "
value to adjust the voltage to be
6. Connect a digital voltmeter to test point "
and chassis ground (-).
3
7. Select group no. "
", item no. "
value to adjust the voltage to be
8. Connect a digital voltmeter to test point "
and chassis ground (-).
3
9. Select group no. "
", item no. "
value to adjust the voltage to be
b
Black Level adjustment
1. Receive the 16-step grey scale computer signal.
2. Set to COMPUTER mode.
3. Enter the service mode.
4. Connect an oscilloscope to test point "
and chassis ground (-).
3
5. Select group no. "
", item no. "
value to adjust amplitude "a" to be
6. Connect an oscilloscope to test point "
and chassis ground (-).
3
7. Select group no. "
", item no. "
value to adjust amplitude "a" to be
8. Connect an oscilloscope to test point "
and chassis ground (-).
3
9. Select group no. "
", item no. "
value to adjust amplitude "a" to be
TP25R1
0
" and change data
7.30
±0.05V.
TP25G1
1
" and change data
7.30
±0.05V.
TP25B1
2
" and change data
7.30
±0.05V.
TP25R1
3
" and change data
10.0
±0.1V.
TP25G1
4
" and change data
10.0
±0.1V.
TP25B1
5
" and change data
10.0
±0.1V.
black level