Optical Parts Disassemblies
m
Polarized Glass-Out/Pre-Polarized Glass removal
1
A
Remove 4 screws
(M2.5x4) and take the LCD/Prism ass'y off upward
from the optical unit.
2
B
Remove each screw
Note:
Do not replace the LCD panel
separately otherwise it can
not obtain proper picture.
,
Optical Unit Top removal
1
Remove 9 screws (M3x10) to take the Optical Unit Top off upward.
and take the glass off upward.
A
LCD Panel/
A
A
Prism Ass'y
Fig.7-
LCD Panel/Prism
Ass'y
* Glasses should be placed as the
film attached side comes to the
LCD panel side.
1
-17-
Polarized Glass-Out
B
Optical filter
LCD Panel
Fig.7-
Optical Unit Top
Fig.8