Sharp MD-MT877S Service Manual page 15

Portable minidisc recorder
Table of Contents

Advertisement

EEPROM (IC402) writing procedure
1. Procedure to replace EEPROM and write initial
value of microcomputer in EEPROM
(1) Replace EEPROM.
(2) Refer to the latest EEPROM data list.
(3) Start the test mode. (Refer to page 12 "Entering the
TEST mode".)
(4) Version display (At the time of settlement of the test
mode by the button operation.)
[ V e r .
(5) The whole LCD lights.
(6) Test mode stop state.
[
T E S T
2. Temperature reference setting method
[1] Measurement, calculation and setting procedure
(1) Set the TEST mode.
(2) Start the EEPROM mode 'Temp' menu.
Button operation in order of BASS, FAST REVERSE x
1 time, PLAY, PLAY in the test mode STOP state.
'TM$$%%' is displayed. ($$= Temperature code, %%
= Temperature reference)
(3) Once press FAST FORWARD, and determine the dis-
played microcomputer TEMP input AD value.
'TPin##' is displayed. (## = TEMP input AD value)
[2] Temperature measurement value correction table
Ambient
temperature
o
o
+ 8
C ~ +10
C
+11
o
C ~ +13
o
C
+14
o
C ~ +16
o
C
+17
o
C ~ +19
o
C
o
o
+20
C ~ +22
C
o
o
+23
C ~ +25
C
o
o
+26
C ~ +28
C
o
o
+29
C ~ +30
C
o
o
+31
C ~ +33
C
]
EEPROM version (c ~ z)
Microcomputer ROM
version
]
Temperature
Center
correction
temperature
- 05h
+ 9.1
- 04h
+ 12.0
- 03h
+ 14.9
- 02h
+ 17.8
- 01h
+ 20.7
00h
+ 23.6
+ 01h
+ 26.9
+ 02h
+ 29.4
+ 03h
+ 32.3
(7) Press the "BASS" button, and press 1 time the "FAST
REVERSE" button.
(8) Perform the operation to display "EEPROM SETTING
MODE CHART", compare the EEPROM DATA LIST
with the display, and set according to the EEPROM
DATA LIST with the VOLUME+ or VOLUME– button.
(9) Set the temperature reference. (Refer to the Tempera-
ture reference setting method.)
(10) Set according to the EEPROM DATA LIST.
(11) Press the STOP button.
(12) Press the STOP button.
(13) After data is written in EEPROM, turn off power .
(4) At the ambient temperature, determine the tempera-
ture corrected value from the temperature measure-
ment value correction table.
(5) Determine the temperature reference, using the follow-
ing formula.
Temperature reference = Microcomputer TEMP input
AD value + Temperature corrected value.
(6) Set the temperature reference value by button opera-
tion, and check whether the temperature code indica-
tion corresponds to "Temperature Code Identification
Table".
[3] Temperature code identification
Check that the temperature code indicated after the servo
control corresponds to the temperature limits below
Ambient
o
C
temperature
o
C
- 9
o
C ~ +10
o
C
+ 3
o
C ~ +21
o
C
+15
o
C ~ +33
o
C
o
+26
C ~ +43
o
C
o
C
o
C
o
C
– 15 –
MD-MT877/MD-MT877C
[ E E P R O M ]
[
T E S T
]
Temperature
correction
o
C
08h
o
C
07h
o
C
06h
o
C
05h
Center
temperature
+ 0.5
o
C
+ 12.0
o
C
+ 23.6
o
C
o
+ 35.0
C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Md-mt877Md-mt877csMd-mt877cMd-mt877(s)

Table of Contents