Zanussi ZDC37200W User Manual page 5

Product manaul
Hide thumbs Also See for ZDC37200W:
Table of Contents

Advertisement

carpets, strips of wood or similar. This might
cause heat built-up which would interfere
with the operation of the appliance.
Important!
• The hot air emitted by the tumble dryer can
reach temperatures of up to 60°C. The appli-
ance must therefore not be installed on floors
which are not resistant to high temperatures.
• When operating the tumble dryer, the room
temperature must not be lower than +5°C
and higher than +35°C, as it may affect the
performance of the appliance.
• Should the appliance be moved, it must be
transported vertically.
• The appliance must not be installed behind
the lockable door, a sliding door a door with a
hinge on the opposite side to that of the ap-
pliance in such a way that a full opening of
the dryer is restricted.
Ensure min. 5cm free space around the appli-
ance.
Removing transport safety packaging
Caution! Before use all parts of the
transport packaging must be removed.
1. Open loading door
www.zanussi.com
2. Pull off adhesive
strips from inside ma-
chine on top of drum.
3. Remove foil hose and polystyrene padding
from the machine.
Electrical connection
Details on mains voltage, type of current and the
fuses required should be taken from the rating
plate. The rating plate is fitted near the loading
aperture (see "Product description" chapter).
Connect the machine to an earthed socket, in
accordance with current wiring regulations.
Warning! The manufacturer declines
any responsibility for damage or
injury through failure to comply with the
above safety precautions.
Should the appliance power supply cable
need to be replaced, this must be carried
out by an authorised service engineer or a
qualified electrician. .
The appliance is supplied with a 13 amp plug
fitted. In the event of having to change the fuse
in the plug supplied, a 13 amp ASTA approved
BS 1363/A fuse must be used.
4
1
The wires in the mains lead are coloured in ac-
cordance with the following code:
Blue - Neutral
1
cord clamp
2
Brown - Live
3
Green and Yellow - Earth
4
The wire coloured green and yellow must be
connected to the terminal marked with the letter
«E» or by the earth symbol
and yellow.
3
2
or coloured green
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents