10.8 Solenoid - diagram 10.3
Remove the electrical plug from the multifunctional control.
Remove the securing screw and then the solenoid Assembly.
10.9 Main Burner
Remove the main burner as Section 8.3.
10.10 Main Injector
Remove the main burner as Section 8.3.
Remove the main injector as Section 8.4.
10 Replacement of Parts
35
RESTRICTOR
EXTENDED
SECURING
PILOT PIPE
SCREWS (8)
TUBING NUT
SOLENOIDS
SECURING
SCREW
ELECTRICAL
PLUG
Diagram 10.3
221659B