Saunier Duval ISOFAST F 28 E Installation And Operating Instructions Manual page 16

Wall mounted modulating combination boiler
Table of Contents

Advertisement

COMMISSIONING
Lighting the boiler :
Make sure that:
The boiler is connected to the electrical supply.
The gas service cock is open.
Then follow the instructions below :
Press the On/Off button (1)
1
The pressure must be between 1 and 2 bar. If not, the system must be filled by a competent person.
To stop the boiler : Press button (1)
Setting to the WINTER position
(Heating + hot water)
Press the mode button to select the winter symbol
Appuyer sur mode pour sélectionner la position hiver
2
10
C
The actual temperature
Température actuelle
of the heating system
dans le circuit chauffage
Adjusting the heating temperature
Press + or - to adjust the maximum temperature
Appuyer sur + ou - pour ajuster la température
of the heating (38 C to 87 C)
maximale souhaitée du circuit chauffage
Visual indication of set temperature
Visualisation de la température demandée
3
60
C
1 6
1.5
bar
1.5
mode
bar
Illuminates when
Apparaît lorsque le
the boiler lights
brûleur fonctionne
mode
1
13
mode
Adjust heating temperature to maximum .
Check that any external controls, if fitted, are
calling for heat (set room thermostat to maximum).
Allow the temperature to rise to the maximum
value, with all radiator valves open. The tempera-
ture rise will cause release of the gases contained
in the water of the central heating system.
Gases driven towards the boiler will be automati-
cally released through the automatic air vent.
The gases trapped at the highest point of the sys-
tem must be released by bleeding the radiators.
On reaching maximum temperature, the boiler
should be turned off and the system drained as
rapidly as possible whilst still hot.
Refill system to a pressure of between 1 and 2
bar and vent as before.
Restart boiler and operate until a maximum tem-
perature is reached. Shut down boiler and vent
heating system. If necessary, top up heating sys-
tem and make sure that a pressure of 1 bar is indi-
cated when system is COLD.
O
I
1
0
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Isofast f 35 e