Saunier Duval Ecosy 2 28E Instructions For Use Installation And Servicing page 10

Condensing combination boiler
Table of Contents

Advertisement

3.4 Terminal Guard
A terminal guard is required if persons could come into contact
with the terminal or the terminal could be subject to damage.
If a terminal guard is required, it must be positioned to provide
minimum of 50mm clearance from any part of the terminal and
be central over the terminal.
The guard should be similar to that shown in diagram 3.5.
A suitable guard can be obtained from.
Tower Flue Components
Morley Rd.
Tonbridge
Kent
TN9 1RA.
Their Reference CGD K3 BL.
3.5 Timber Frame Buildings
If the boiler is to be installed in a timber frame building it should
be fitted in accordance with the Institute of Gas Engineers
document IGE/UP/7/1998. If in doubt seek advice from the local
gas undertaking or Hepworth Heating Ltd.
3.6 Room Ventilation
The boiler is room sealed, so when it is installed in a room or
space, a permanent air vent is not required.
3.7 Cupboard or Compartment Ventilation
Due to the high efficiency and hence low casing temperature of
this boiler, cupboard or compartment ventilation is not necessary.
TERMINAL GUARD
221874A
3 Flue Location and Ventilation
Diagram 3.5
10
A
A
F
A
G
E
G
UNDER CAR PORT etc.
MINIMUM SITING DIMENSIONS FOR
FANNED FLUE TERMINALS
POSITION
A
DIRECTLY BELOW, ABOVE OR
HORIZONTALLY TO AN OPENING, AIR
BRICK, OPENING WINDOWS, AIR VENT
OR ANY OTHER VENTILATION OPENING
B BELOW GUTTER, DRAIN/SOIL PIPE
C BELOW EAVES
D BELOW A BALCONY OR CAR PORT 200
E FROM VERTICAL DRAIN PIPES AND
SOIL PIPES
F FROM INTERNAL CORNERS
G ABOVE ADJACENT GROUND OR
BALCONY LEVEL
H FROM SURFACE FACING THE
TERMINAL
I
FACING TERMINALS
J FROM OPENING (DOOR/WINDOW)
IN CAR PORT INTO DWELLING
K VERTICAL FROM A TERMINAL
L HORIZONTALLY FROM A TERMINAL 300
M FROM EXTERNAL CORNERS
*
It may be necessary to increase this dimension to prevent
staining of adjacent walls depending on weather conditions.
C
B,C
B,C
K
L
L
G
K
K
M
F
F
G
G
D
J
F
K
H,I
MM
300
75
200
75
300
300
600
1200
1200
1500
300
Diagram 3.4
*
*