DIP Switch Settings:
Display Hold OFF − Set switch 1 so the depressed section is toward OPEN as labeled on the switch.
Displays will not hold values. The voltage displayed while welding is an average reading over a time span of
6 to 8 seconds. If the weld time is less than 8 seconds, the voltage displayed may not be accurate.
Display Hold ON (Factory Default) − Set switch 1 so the depressed section is toward 1 as labeled on the
switch.
Displays will hold their last value for five seconds after the trigger is released. The voltage displayed while weld-
ing is an average reading over a time span of 6 to 8 seconds. If the weld time is less than 8 seconds, the voltage
displayed may not be accurate.
Display Amperage − Set switch 2 so the depressed section is toward OPEN as labeled on the switch.
Wire Speed / Amps Display will display Amps while welding and Wire Speed while not welding. If the hold func-
tion is enabled, Amps will be displayed during hold also.
Do Not Display Amperage (Factory Default) − Set switch 2 so the depressed section is toward 2 as labeled
on the switch.
Wire Speed / Amps Display will display only Wire Speed.
Wire Speed - Meters Per Minute − Set switches 3 and 4 so the depressed sections are toward OPEN as
labeled on the switch.
Displays Wire Speed in Meters per Minute.
Wire Speed - Inches Per Minute − Set switches 3 and 4 so the depressed sections are toward 3 and 4 as
labeled on the switch.
Displays Wire Speed in Inches per Minute.
Display Feeder Information − Set switch 5 so the depressed section is toward OPEN as labeled on the switch.
With switch in ON position, at feeder power up, feeder will display various sets of information. Each set of infor-
mation will be displayed for three seconds.
Display Board (PC22) Software Part Number −
Top display will show the first three digits, bottom display will show last three digits of the Display board (PC22)
software revision level.
Motor Board (PC1) Software Part Number −
Top display will show the first three digits, bottom display will show last three digits of the Motor board (PC1)
software revision level.
Accumulated Weld Time −
This is the time the feeder has actually been used for welding. This information will be displayed in two halves.
First being years and days, second in hours and minutes. Top display will show years/hours, bottom display
will show days/minutes.
Do Not Display Feeder Information (Factory Default) − Set switch 5 so the depressed section is toward 5
as labeled on the switch.
Feeder information is not displayed.
Ref. 805 200-B
OM-237 323 Page 21