Installing Gas Supply - Miller Millermatic 251 Owner's Manual

Arc welding power source and wire feeder
Hide thumbs Also See for Millermatic 251:
Table of Contents

Advertisement

4-9. Installing Gas Supply

.
DO NOT use Argon/Mixed gas regulator/flowmeter
with CO
shielding gas. See Parts List for optional
2
CO
gas regulator/flowmeter.
2
4
7
5
6
Rear Panel
Return To Table Of Contents
Obtain gas cylinder and chain to
running gear, wall, or other
stationary support so cylinder
cannot fall and break off valve.
1
2
1
Remove cap, stand to side of
valve, and open valve slightly. Gas
flow blows dust and dirt from valve.
Close valve.
2
3
4
Install so face is vertical.
5
3
6
Connect customer supplied gas
hose between regulator/flowmeter
Argon Gas Or
gas hose connection, and fitting on
Mixed Gas
rear of welding power source.
7
Typical flow rate is 20 cfh (cubic
feet per
manufacturer's
flow rate.
Tools Needed:
1-1/8, 5/8 in
Cap
Cylinder Valve
Cylinder
Regulator/Flowmeter
Regulator/Flowmeter Gas
Hose Connection
Welding Power Source Gas
Hose Connection
Flow Adjust
hour).
Check
wire
recommended
802 028-A / Ref. 802 477-B