Conettix ITS-D6686-INTL | Installation Guide | 3.0 Configuring and Programming the D6686
3. Open the D6200 software and select
Network – Network Utilities - Network
Device Setup as shown below
4. Select List All Conettix IP Devices tab
and click the Start button. The program
will scan the network for the device.
5. The D6686 will be shown in the list with
the IP address. Record the IP address
that is listed is shown.
6. Select XML Configuration tab and click
the Setting button. Enter in the Setting
dialog:
D6686/D6100IPv6 IP: The IP address
recorded in the previous step
FTP User Name: admin
FTP Password: PASS
Click OK
6
7. Click the Open XML button, select
D6686.xml, and click Open.
8. Make changes to the parameters that are
required for your particular installation
scenario by selecting the specific item,
enter the required changes, and click
Change. The values that are changed will
be displayed in
the programmable configuration
parameters are listed on the next page
with the valid values.