HP Cisco MDS 8/12c Release Note page 38

Cisco mds 9000 family release notes for cisco mds nx-os release 5.2(1) (ol-25090-01, july 2011)
Hide thumbs Also See for Cisco MDS 8/12c:
Table of Contents

Advertisement

Caveats
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Symptom: On the storage VDC of the switch, the default gateway and the IP address of the switch
may not be reachable if they are configured using the setup script. This issue can occur when you
use the setup script to configure the default gateway and IP address. The default gateway and IP
address should be configured manually in the "default" VRF.
Workaround: Reconfigure the default-gateway and IP address in the "default" VRF
CSCtq88900
Symptom: In an SME or IOA deployment, if the number of H->T flows that are added exceeds 512,
then subsequent disruptive platform events can leave an FCR unable to process interprocess (MTS)
messages at a rate fast enough to support the scaled configuration. This situation can cause an
MTS-buffers full condition in the FCR, which can result in unpredictable behavior. Some of the
resulting errors may be unrecoverable, and may require a disruptive restart of the flows.
Workaround: Use CFS regions if a large number (greater than 512) of application flows need to be
configured. CFS regions segment the FCR peer topology into manageable proportions.
CSCtr27068
Symptom: The port-group monitor feature is disabled on the 48-port 8-Gbps Advanced Fibre
Channel switching module (DS-X9248-256K9).
Workaround: None.
CSCtr27150
Symptom: The port-group monitor feature is disabled on the 32-port 8-Gbps Advanced Fibre
Channel switching module (DS-X9232-256K9).
Workaround: None.
CSCtr36554
Symptom: The feature manager causes high CPU usage on the standby supervisor. This issue occurs
when the feature manager gets into a loop of sending messages to itself.
Workaround: Reload the standby supervisor.
CSCtr49389
Symptom: The system health serdes-loopback int fc-port-range command that tests the health of
a port using the serdes loopback on the 48-port 8-Gbps Advanced Fibre Channel switching module
(DS-X9248-256K9) and the 32-port 8-Gbps Advanced Fibre Channel switching module
(DS-X9232-256K9) fails if there is no SFP attached to the port. The following message is displayed:
Serdes loopback test on fcx/y failed. Failure reason: failed to initialize for
testing.
Workaround: Attach an SFP to the port so that the test can pass and the port can come up.
CSCtq35662
Symptom: Due to an ASIC issue, there are no credits reserved for high priority traffic on the 48-port
8-Gbps Advance Fibre Channel switching module. As a result, for a long-distance connection, port
credits may go to zero, which can cause the fabric merge to fail. This issue might be seen when a
fabric merge fails for a long-distance ISL.
Workaround: None.
CSCtq42878
Symptom: When you configure dynamic port VSAN membership (DPVM) using device alias and
then remove the alias before clearing the DPVM configuration, the node NWWN configuration will
not take effect for the device when you enter the activate force command. This issue might be seen
when you configure a device in DPVM using device alias, and then remove the device alias mapping
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(1)
38
OL-25090-01

Advertisement

Table of Contents
loading

Table of Contents