Configuring Irf Bridge Mac Persistence - HP 6125G Configuration Manual

6125 blade switch series irf configuration guide
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Step
1.
Enter system view.
2.
Configure the description of
a member.

Configuring IRF bridge MAC persistence

An IRF fabric by default uses the bridge MAC address of the master switch as its bridge MAC address.
This bridge MAC address is used by Layer 2 protocols, for example, LACP, to identify the IRF fabric, and
must be unique on a switched LAN for proper communication.
To avoid duplicate bridge MAC addresses, an IRF fabric can automatically change its bridge MAC
address after its master leaves, but the change can cause transient traffic interruption.
Depending on your network condition, enable the IRF fabric to preserve or change its bridge MAC
address after the master leaves. Available options include:
irf mac-address persistent timer—Bridge MAC address of the IRF fabric persists for six minutes after
the master leaves. If the master does not come back before the timer expires, the IRF fabric uses the
bridge MAC address of the new master as its bridge MAC address. This option avoids unnecessary
bridge MAC address change due to a device reboot, transient link failure, or purposeful link
disconnection.
irf mac-address persistent always—Bridge MAC address of the IRF fabric does not change after
the master leaves.
undo irf mac-address persistent—Bridge MAC address of the new master replaces the original one
as soon as the old master leaves.
IMPORTANT:
If ARP MAD is used, configure the undo irf mac-address persistent command to enable immediate bridge
MAC address change after a master leaves.
If two IRF fabrics have the same bridge MAC address, they cannot merge.
To change the bridge MAC persistence setting from permanent to any other mode, you must make sure
the master device at the time when permanent persistence was enabled is still in the IRF fabric, whether
as the master or a subordinate.
To configure the IRF bridge MAC persistence setting:
Step
1.
Enter system view.
Command
system-view
irf member member-id description text
Command
system-view
19
Remarks
N/A
By default, no member switch
description is configured.
Remarks
N/A

Advertisement

Table of Contents
loading

This manual is also suitable for:

6125g/xg

Table of Contents