Condenser
A dirty or clogged condenser:
• Prevents proper airflow.
• Reduces ice making capacity.
• Causes higher than recommended operating
1. Unplug the icemaker or disconnect power.
2. Remove the 2 screws in the lower access
3. Pull the bottom forward and then pull down
14
temperatures which may lead to component
failure.
panel and the 2 screws from the base grille
area of the front panel support. Pull forward
to remove the lower access panel.
to remove the lower access panel.
Care and Cleaning
Icemaker
4. Remove dirt and lint from the condenser
fins and the unit compartment with a brush
attachment attached to a vacuum cleaner.
5. Replace the lower access panel using the
4 screws.
6. Plug in the icemaker or reconnect power.