Operation

Placing the UPS in Operate Mode

The UPS can be placed in Operate mode if either of the following conditions apply:
The UPS is powered up and in Standby mode (unit is plugged in, utility power is present,
and none of the front panel LEDs are illuminated).
The UPS is powered down and no utility power is available.
Press and hold the On/Standby button (2). The Utility LED (1) initially illuminates solid
green, then the UPS continues with a series of beeps and LED flashes. When the Utility LED
remains illuminated solid green, power is available at the UPS output receptacles.
IMPORTANT: If the UPS is running on battery power (no utility power is present), press and hold the
On/Standby button (2) until the audible alarm sounds.
Figure 2-3: Placing the UPS in Operate mode
2-4
HP CONFIDENTIAL Codename: Sherman7 Part Number: 215420-002 Last Saved On: 10/4/02 10:27 AM
1
2
HP Uninterruptible Power System T700 Models User Guide