Mitsubishi Electric MXZ-24UV-E1 Service Manual page 6

Split-type, heat pump air conditioner
Table of Contents

Advertisement

Indoor units
Unit A
combination
07
3.2
4.0
09
12
6.0
18
7.1
07+07
3.2
07+09
3.2
07+12
3.2
07+18
2.8
09+09
4.0
09+12
3.5
09+18
3.25
12+12
4.5
12+18
4.1
18+18
4.5
07+07+07
2.87
07+07+09
2.75
07+07+12
2.3
07+07+18
2.15
07+09+09
2.6
07+09+12
2.2
07+09+18
2.0
09+09+09
3.0
09+09+12
2.55
NOTE: SLH-1AR is equivalent to class 09 (9000BTU).
MCFH-13NV, SEH-1.6AR, SLH-1.6AR is equivalent to class 12 (12000BTU).
MCFH-18NV, SEH-2AR,SLH-2AR is equivalent to class 18 (18000BTU).
Heating capacity (kW)
Unit B
Unit C
3.2
4.0
5.4
6.2
4.0
5.3
5.75
4.5
4.9
4.5
2.87
2.87
2.75
3.5
2.3
4.4
2.15
4.7
3.2
3.2
2.7
4.1
2.5
4.5
3.0
3.0
2.55
3.9
NOTE: Electrical data is for outdoor unit only.
Outdoor unit
power consumption
Total
3.2
(0.9-4.1)
(270-1600)
4.0
(0.9-4.8)
(270-1700)
6.0
(0.9-7.2)
(270-2570)
7.1
(0.9-7.8)
(270-2830)
6.4
(1.8-7.2)
(470-2300)
7.2
(470-2680)
(1.8-8.7)
8.6
(1.8-10.6)
(470-3800)
9.0
(1.8-10.9)
(470-3880)
8.0
(1.8-10.1)
(470-3560)
8.8
(1.8-10.8)
(470-3850)
9.0
(1.8-10.9)
(470-3880)
9.0
(1.8-10.9)
(470-3880)
9.0
(470-3880)
(1.8-10.9)
9.0
(1.8-10.9)
(470-3880)
8.6
(2.1-10.6)
(520-3000)
9.0
(2.1-10.9)
(520-3180)
9.0
(2.1-10.9)
(520-3180)
9.0
(2.1-10.9)
(520-3180)
9.0
(2.1-10.9)
(520-3180)
9.0
(2.1-10.9)
(520-3180)
9.0
(2.1-10.9)
(520-3180)
9.0
(2.1-10.9)
(520-3180)
9.0
(2.1-10.9)
(520-3180)
6
Current
(A)
(W)
1130
5.46
1320
6.38
1900
9.23
2300
11.11
1930
9.32
2050
9.90
2550
12.32
2730
13.19
2350
11.35
2640
12.75
2730
13.19
2730
13.19
2730
13.19
2730
13.19
2420
11.69
2500
12.08
2500
12.08
2500
12.08
2500
12.08
2500
12.08
2500
12.08
2500
12.08
2500
12.08
Power
factor
(%)
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxz-24uv-e2