Technical Specifications

Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2-cm (4-in) clearance on front side and power supply side of the computer to permit the required airflow.
If within an enclosure, the front side should be 100% open. The clearance between the system and the cabinet must be at least
10 mm (0.4 inch) on the sides and top and at least 50-mm (2-inch) clearance in the rear with power supply venting area 100%
open per the above bullet.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
Temperature Range
Relative Humidity
Maximum Altitude
(unpressurized)
*NOTE: Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency Range
Rated Input Current
Heat Dissipation
Power Supply Fan
ENERGY STAR Compliant
FEMP Standby Power Compliant
(<2W in S5 – Power Off)**
Power Consumption in ES Mode –
Suspend to RAM (S3)
(Instantly Available PC)
Processor/Cache Memory Power -
Down (S3)
Optical Drive Spins Down When Not
In Use
HP rp5700 Point of Sale (POS) System or HP rp5700
240-watt – 80 PLUS power supply – Active PFC
5 A @ 90 VAC (3.5 A @ 90 VAC with 80% efficient power supply*)
DA - 12703 North America — Version 32 — June 21, 2013
Operating: 50° to 104 F (10° to 40° C)*
Non-operating: -22° to 140° F(-30° to 60° C)
Operating: 20% to 85% (non-condensing at ambient)
Non-operating: 5% to 90% (non-condensing at ambient)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
90 to 264 VAC
100 to 240VAC
50/60 Hz
47 – 63 Hz
Standard power supply:
Typical 340 btu/hr (86 kg-cal/hr)
Maximum 1260 btu/hr (397 kg-cal/hr)
80% efficient power supply:
Typical 273 btu/hr (69 kg-cal/hr)
Maximum 1024 btu/hr (258 kg-cal/hr)
80 mm variable speed fan
Yes