Functional Execution Command; Format; Command Pipelining; Transfer Example - Canon LV-7292A Command Specifications

Basic serial command specifications
Hide thumbs Also See for LV-7292A:
Table of Contents

Advertisement

LV-7292A/LV-7297A/LV-7392A/LV-7393A/LV-7398A/LV-8227A/LV-7292M/LV-7297M/

Functional Execution Command

6.1. Format

6.1.1 PC issues a command in format as below.
"C" COMMAND [CR]
Command: two characters (See Basic Functional Execution Command Table)
A projector changes received data to decode and returns a result after being
ready to receive next command.
[ACK] CR (0x06 0x0D)When received Functional Execution Commands.
6.1.2 " " CR When the received data cannot be decoded.

6.2. Command Pipelining

When some functions need the command pipelining, the performance is the same as that of the
remote control;
6.2.1. System: issues any command every 100 ms.
6.2.2. When receiving the appropriate command, the function is executed for 120 ms from the
moment.
6.2.3. When receiving the same command continuously within 120 ms, the function is executed
for another 120 ms from the moment.
6.2.4. When there is no incoming command after 120 ms, the execution of pipelining is stopped.
6.2.5. When the projector receives other incoming commands within 120ms, the execution of
pipelining is stopped.

6.3. Transfer Example

Switch the projector to video mode with Basic Command.
PC → Projector
Projector → PC
LV-8227M/ LV-7292S/LV-7297S/LV-7392S
Command
"C" "0" "7"
-7-
Basic Serial Command Specifications
CR
ACK
Processing
(A few ms
5s)
CR

Advertisement

Table of Contents
loading