Download Print this page

Specifications - Lenovo Smart 750XLa Specifications

Ups system

Advertisement

• Line-interactive Automatic Voltage Regulation (AVR)
maintains selectable 120V, 110V or 100V nominal output
during brownouts as low as 83V and overvoltages to 145V
• Network interfaces support simultaneous communications
via built-in USB port, DB9 serial port and SNMPWEBCARD slot
• HID-compliant USB interface enables integration with
built-in power management and auto shutdown features of
Windows
®
and Mac OS X
• Included PowerAlert UPS monitoring software supports
safe unattended shutdown, monitoring and control via local
connected servers, plus any number of additional servers
over IP
• UPS interface supports on-battery, low-battery,
power-restored, AC-voltage, DC-voltage, output current

SPECIFICATIONS

Output
Output Volt Amp Capacity (VA)
Output Watt Capacity (watts)
Nominal Output Voltage(s)
Supported
Frequency Compatibility
Output Voltage Regulation
(line mode)
Built-in UPS Output
Receptacles
Battery
Full load runtime (minutes)
Half load runtime (minutes)
Expandable battery runtime
External battery pack
compatibility
DC System Voltage (VDC)
Battery recharge rate
(included batteries)
Replacement battery
cartridge (internal UPS
battery replacement)
Battery access
LEDs Alarms and Switches
LED Indicators
Alarms
Switches
750
500
100V, 110V, 120V
60Hz
-13%, +15%
8 5-15R outlet(s)
10 minutes (500W)
27 minutes (250W)
Runtime is expandable with
BP24V28-2U (limit 1) or
BP24V70-3U (multi-pack
compatible)
BP24V15RT2U
24
Less than 4.5 hours from
10% to 90%
RBC24-SLT
Supports battery access
and hot-swap replacement
without powering connected
equipment off
9 LEDs indicate line power,
battery power, AVR,
overload and replace battery
status—with a 3-LED level
meter for load and battery
charge level
Audible alarm warns of
power failure condition
Includes two pushbutton
switches for on/off power
control and self-test/
alarm cancel functions.
Also includes two dip switch
controls for setting the
nominal voltage
monitoring, battery charge current, battery capacity, timed
inverter shutoff, activate self-test and output power
control
• NEMA 5-15P input plug; 8 battery-supported NEMA 5-15R
output receptacles
• Dataline surge suppression protects dialup, DSL or
network Ethernet connection
• Front panel LEDs offer current monitoring, voltage
regulation and battery charge level information
• UPS ships fully assembled in full compliance with DOT
regulations; no time-consuming connection of internal
batteries by user required
• 2-year warranty;
250,000 Ultimate Lifetime Insurance
$
(U.S. and Canada only)
Input
Rated input current
(at maximum load)
Nominal input voltage(s)
supported
UPS input connection type
UPS input cord length (ft)
Recommended electrical
service
Voltage compatibility (VAC)
Voltage Regulation
Voltage regulation
description
Overvoltage correction
Undervoltage correction
Surge/Noise Suppression
UPS AC suppression joule
rating
EMI/RFI AC noise
suppression
AC suppression response time
Dataline suppression
5.4A (120V), 5.8A (110V),
6.4A (100V)
100V AC, 110V AC, 120V AC
5-15P
6ft
120V, 15A
120
Automatic Voltage
Regulation (AVR) circuits
maintain clean, regulated
computer-grade 120,
110, 100V nominal output,
without using battery
power, during brownouts
95V (120V), 87V (110V),
83V (100V)
Input voltages between 127V
and 145V (120V), 116 and
133 (110V), 111 and 121
(100V) are reduced by 12%
Voltage boost of 14%
applies when input is 95
– 108 (120V), 87 – 99
(110V), 83 – 90 (100V)
570J
Yes
Instantaneous
Includes 8-wire RJ45 jack;
pins 1, 2, 3 and 6 provide
10baseT Ethernet line
surge suppression with
7 .5V clamping; pins 4 and
5 provide single-line tel/
DSL line surge suppression
starting at 260V

Advertisement

loading