Test Of The Step Motor Drive Pulse; Timer Test And Memory Test - DURKOPP ADLER 743-221 Accessory Manual

Instructions for programming da microcontrol
Hide thumbs Also See for 743-221:
Table of Contents

Advertisement

4.8 Test of the Step Motor Drive Pulse

4.9 Timer Test and Memory Test

Program 57 checks the step motor controller and the outputs of the
step motor.
Set the " Program " switch to " 57 ".
Press the " STOP " key.
The testing program is activated.
The results appear.
Display
Explanation
AMP ERR
Error in the output or transmission cable
not plugged in
LINK OK
Transmission to the controller OK
LINK ERR
Error in the transmission
EPROM OK
EPROM OK
EPRO ERR
EPROM defective
XCOU OK
Counter component for cycle counting OK
XCOU ERR
Counter component for cycle counting defective
SCOU OK
Counter component for cycle generation OK
SCOU ERR
Counter component for cycle generation defective
ATTENTION !
This program erases all stored values.
Sewing lengths, blower activation period and all other values must be
reset.
The working memory and the timer switchings are checked by the
program independently.
Set the " Program " switch to " 59 ".
Press the " STOP " key.
The program is activated.
Display
Explanation
OK
Working memory and timer are OK
ERROR 0
RAM error
ERROR 6
Timer 1 defective
ERROR 7
Timer 2 defective
15

Advertisement

Table of Contents
loading

Table of Contents