  • Page 1 Plena Weekly Timer Installation and User Instructions PLN-6TMW...
  • Page 2: Important Safeguards

    (9922 141 7014x). These instructions are supplied together with all equipment that can be connected to the mains. Thank you for choosing a Bosch Security Systems product. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 3: Table Of Contents

    8. Plena Weekly Timer Configuration software ..................... 27 Introduction .................................... 27 System requirements ................................27 Installing the software ................................. 27 Connecting to a PC ................................29 Starting the software ................................29 Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 4 Mechanical ................................... 39 Interconnection ..................................39 Environmental ..................................39 Controls and indicators ..............................39 Clock accuracy (without sync) ............................39 9.10 Power supply ..................................39 9.11 Parts included ..................................39 Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 5: Introduction

    • Warning Persons can be (severely) injured, or the equipment can be seriously damaged, if the alert is not observed. • Danger Not observing the alert can result in death. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 6: Conversion Tables

    1.3: Conversion of units of pressure 1 psi = 68.95 hPa 1 hPa = 0.0145 psi Note 1 hPa = 1 mbar. °F --- °C ⋅ °C ⋅ °F 32 – Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 7: System Overview

    ‘All-in-One’ system • a voice alarm system • a timer • a charger The various elements are designed to complement each other thanks to matched acoustical, electrical and mechanical specifications. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 8 Plena Weekly Timer | Installation and User Instructions | System overview en | 8 Intentionally left blank. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 9: Equipment

    Timer to a large number of times in the general system settings. separate display. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 10 Display External Display AC / DC Power Supply ±5V 230V Power Supply 115V Block Converter DC / DC Converter figure 3. 1 : Schematic overview of the Plena Weekly Timer Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 11: Controls, Connectors And Indicators

    7 Reset button - for resetting the software of the Timer (use a pin to activate the small button) 8 Rotary selector - for selecting and confirming settings figure 3.2: Front panel Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 12: Display

    (see table 7.2) 15 Day of the week 16 Hold - indicates that all controls on the front panel are locked (see section 6.5) 9 10 13 14 figure 3.3: Main display Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 13: Rear Panel

    11 USB connector - for connecting external PC 12 Earth connection screw 13 Voltage selector (115V/ 230V) 14 ON - OFF switch 15 Mains connector (3-pole) figure 3.4: Rear panel Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 14: Installation

    (12) to the unit to increase the electrical stability of the system. figure 3.5: Brackets for rack-mounting 1 2 V 1 2 V figure 3.6: Back-up battery connections Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 15: Connecting Other Plena Devices

    “Mixer Amplifier XLR in” (preferred set-up). The “Timer cinch out” can also be connected to the “Mixer Amplifier cinch in”. PLN-DVDT PLN-6TMW LBB-1903 figure 3.7: Connecting other Plena devices Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 16: Power

    (see figure 3.8). 3 Use the mains lead to connect the Timer to the power supply (see figure 3.8). figure 3.8: Mains lead Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 17: Switch On And Off

    Program LEDs (1) and Contact LEDs (2) on the front of the Timer will be momentarily lit during initial system power up, and the main display will come on (see figure 4.2). figure 4.2: Front panel LEDs Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 18 Plena Weekly Timer | Installation and User Instructions | Switch on and off en | 18 Intentionally left blank. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 19: Setting The Date And Time

    Off (up) position. Note To modify the date and time, just press and hold in the Set button. Then repeatedly press the rotary selector to quickly jump to, and change, the settings. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 20 Summer time (daylight saving time). A small symbol of the sun will be displayed. • Press and hold in Program button 2 to switch back to Winter time. The small symbol of the sun will disappear. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 21: Manual Settings

    All controls will remain locked until the rotary selector is pressed and held in again for a number of seconds, and the word “Hold” is no longer displayed. figure 6.2: Manually activating an output contact Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 22 Plena Weekly Timer | Installation and User Instructions | Manual settings en | 22 Intentionally left blank. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 23: Programming A Schedule

    Note If you want to leave the programming sequence at any time without changing the settings, press the Set button. figure 7.2: Programming the day and time of the event Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 24 15 To program the next event, repeat from step 2. 330 Hz (2 s) 659 Hz (1 s), 523 Hz (1 s), 392 Hz (1 s), 330 Hz (2 s) Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 25 (and will ignore the settings of any previous events). For example, if an output contact that was already open is set to open, nothing will happen. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 26: Viewing And Editing Events

    This indicates that editing of the event is complete, and that the Timer is running. • press the rotary selector to confirm the new event as described in step 8 of section 7.2. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 27: Plena Weekly Timer Configuration Software

    • Go to Start > Run. • Enter X:\index.html. (Replace X with the charac- ter of the CD-ROM drive). figure 8.3: Select program manager group figure 8. 1 : Welcome Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 28 [Next]. The software will start to install (see figure 8.5). figure 8.5: Installing the software 6 Wait until the installation is complete. A window similar to the one in figure 8.6 will appear. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 29: Connecting To A Pc

    3 Enter the password (12345678) in the Enter password field, and click the OK button. The main menu will appear (see figure 8.10). Note The default password 12345678 can be changed in the configuration software (see section 8.6.5). Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 30: Main Menu Buttons

    8. 1 0: Main menu 8.6.1 Setup Select Setup, and then Language to set the required language (see figure 8.11). figure 8. 1 1: Language setup option Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 31: System Settings

    (select a number between 1 and 10). Typically this value is normally set to 1, unless you want all programmed chimes to be repeated. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 32: Schedule Programming

    The edit program function for schedule 1 and schedule 2 is identical. Therefore for simplicity, only program 1 is explained. 2 Click the Edit schedule programing 1 button. The Schedule programming window will appear (see section 8.8.1). Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 33: Schedule Programming

    See the explanation of the various fields (Time, Chime, Chime volume, BGM, etc.) on the following page. 3 After changing the parameters, click Save to save your settings. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 34 4 Click the Copy button. 5 Click the day tab (at the top of the window) that you want to paste to. 6 Click the Paste button. The copied events will be inserted. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 35: Upload Configuration

    Make sure you disconnect the USB cable figure 8. 1 5: Programming and upload buttons before using the Timer. If you do not disconnect the USB cable, the performance of the Timer might be affected. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 36: Download Schedule

    If you click No, the software will start to download the schedule from the Plena Weekly Timer to the PC, and the Downloading window will appear (see figure 8.19). When downloading is complete, this window will close. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 37: Modify Password

    The password is also case sensitive. Therefore, pay attention to capital letters when entering the new password. 4 Confirm the password, and then click OK. Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 38: Open Configuration File

    8.23: Open configuration file window 2 Select the configuration file that you want to open, and then click Open. The configuration will be loaded, and displayed on the Schedule programming window (see figure 8.14). Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 39: Technical Data

    Euro socket with built-in fuse PLN-6TMW 24DC back-up power Rack mounting brackets Removable Euro-style screw terminal XLR cable System configuration Mains cable (1.7 m) RJ-45 connector Instructions for use Plena bonus CD Bosch Security Systems | 2006-05 | 9922 141 50741 en...
  • Page 40 Plena Weekly Timer | Installation and User Instructions | Technical data en | 40 Intentionally left blank. Bosch Security Systems | 2006-05 | 9922 141 50741 en...