15

Decommissioning

15
Decommissioning
15.1

Temporarily shutting down the boiler

Caution.
b
Risk of frost damage due to incorrect
shutdown.
If you switch off the boiler using the on/off
switch or disconnect it from the power
mains, this can cause frost damage to the
heating installation.
> Only shutdown the boiler fully if the
heating installation is otherwise pro-
tected from frost.
> Drain the heating installation fully.
2
50
15.1 Switching off the boiler
> Close the gas isolator cock.
> Close the cold water stop valve.
> Drain the heating installation fully
(¬ section 12.2.2).
> Press the on/off switch (1).
The display (2) goes off.
15.2
Taking the boiler permanently out of
service
> Close the gas isolator cock.
> Close the cold water stop valve.
> Drain the heating installation fully
(¬ section 12.2.2).
> Press the on/off switch (1).
The display (2) goes off.
> Isolate the boiler from the power mains.
> Dispose of the boiler correctly (¬ section 15.3).
15.3

Disposing of the boiler

The Vaillant ecoTEC boiler consists primarily of materials
that can be recycled.
68
The boiler and its accessories must not be disposed of with
household waste.
> Make sure that the boiler and any existing accessories
are disposed of properly.
16

Guarantee and customer service

16.1

Factory guarantee

One year guarantee for ecoTEC appliances
Vaillant undertakes to rectify any manufacturing defect that
occurs within twelve months of the installation date.
Registering with us
Registration is simple. Just complete the Guarantee Regis-
tration Card and return to Vaillant within 30 days of instal-
lation. Your details will then be automatically registered
within the Vaillant scheme.
Note: No receipt will be issued.
Immediate help
If your Vaillant boiler develops a fault your first action
should be to contact your installer, as his professional
assessment is needed under the terms of our Guarantee. If
you are unable to contact your installer, phone Vaillant Ser-
vice Solutions: 0870 6060 777
1
16.2

Vaillant Service

To ensure regular servicing, it is strongly recommended
that arrangements are made for a Maintenance Agreement.
Please contact Vaillant Service Solutions
(0870 6060 777) for further details.
Installation and maintenance instructions ecoTEC 0020173113_01