11
Adapting the boiler to the heating installation
Code
Parameters
D.000
Heating partial load
D.001
Overrun time of internal pump for
heating mode
D.002
Max. burner anti-cycling time heating
at 20 °C flow temperature
D.003
Outlet temp. actual value
D.004
Measured value of hot water sensor
D.005
Flow temperature target value (or
return target value)
D.006
Hot water temperature target value
(VUW boilers only)
D.007
Warm start temperature target value
(only with VUW boilers)
Cylinder temperature target value
(only with VU boilers)
D.008
Room thermostat at terminal RT
D.009
Target value from external eBus con-
troller
D.010
Status of internal pump
D.011
Status of external heating pump
D.012
Status of cylinder charge pump
D.013
Status of hot water circulation pump
D.014
Target pump speed (high-efficiency
pump)
D.015
Actual pump speed (high-efficiency
pump)
D.016
Room thermostat 24 V DC open/
closed
D.017
Heating flow/return regulation
changeover
D.018
Pump operating mode setting
D.019
Operating mode of 2-stage pump
D.020
Max. setting for cylinder target value
D.022
Hot water demand via C1/C2, internal
hot water control system
D.023
Summer/winter operating mode (heat-
ing on/off)
D.025
Hot water generation enabled by eBUS
controller
D.026
Auxiliary relay control
11.1 Diagnosis codes
44
Adjustable values
Adjustable heating partial load in kW
Auto: Boiler automatically adjusts max. partial load to cur-
rent system demand
1 - 60 min
2 - 60 min
in °C
Not relevant
In °C, max. of the value set in d.71, limited by an eBUS con-
troller if connected)
35 to 65 °C
40 to 65 °C
15 °C frost protection, then 40 to 70 °C;
(max. temperature can be adjusted under D.020)
Room thermostat open (no heat requirement)
Room thermostat closed (heat requirement)
in °C
1 = on, 0 = off
1 to 100 = on, 0 = off
Not relevant
Not relevant
Not relevant
Not relevant
0 = Room thermostat open (no heating mode)
1 = Room thermostat closed (heating mode)
0 = Flow, 1 = Return
1 = Comfort (continuously operating pump)
3 = Eco (intermittently operating pump)
Not relevant
Not relevant
Not relevant
1 = Heating on, 0 = Heating off (summer mode)
1 = Yes, 0 = No
Not relevant
Installation and maintenance instructions ecoTEC 0020173113_01
Factory
Your own
setting
setting
Auto
5 min
20 min
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
0
3
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble
Not adjusta-
ble