Code
Parameters
D.027
Switching of relay 1 on the
"2 in 7" multi-functional module VR 40
D.028
Switching of relay 2 on the
"2 in 7" multi-functional module VR 40
D.033
Fan speed target value
D.034
Fan speed actual value
D.035
Position of the diverter valve
D.036
Hot water flow quantity
(impeller sensor)
D.039
Solar feed temperature
D.040
Flow temperature
D.041
Return temperature
D.044
Digitised ionisation value
D.046
Pump type
D.047
Outside temperature (with weather-
controlled Vaillant controller)
D.050
Offset for minimum speed
D.051
Offset for maximum speed
D.058
Activation of solar post-heating for VUW
boilers;
Switch hot water mode
D.060
Number of temperature limiter shut-
downs
D.061
Number of ignition device cutoffs
D.064
Average ignition time
D.065
Maximum ignition time
11.1 Diagnosis codes (continued)
Installation and maintenance instructions ecoTEC 0020173113_01
Adapting the boiler to the heating installation
Adjustable values
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = Remote control eBUS (not active)
9 = Legionella protection pump (not active)
10 = Collective solar valve (not active)
1 = Circulation pump
2 = External pump
3 = Cylinder charging pump
4 = Extractor hood
5 = External solenoid valve
6 = External fault message
7 = Solar pump (not active)
8 = Remote control eBUS (not active)
9 = Legionella protection pump (not active)
10 = Collective solar valve (not active)
In rpm
In rpm
0 = Heating; 100 = Hot water; 40 = Mid-position
In l/min
Actual value in °C
Actual value in °C
Actual value in °C
Display range 0 to 1020,
> 800 no flame
< 400 good flame
Not relevant
Actual value in °C
In rpm, setting range: 0 to 3000
In rpm, setting range: -990 to 0
0: Solar post heat mode deactivated
3: DHW activation target value minimum 60 °C
Number of shutdowns
Number of unsuccessful ignitions in the last attempt
In seconds
In seconds
11
Factory
Your own
setting
setting
2
2
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Nominal value
set in factory
Nominal value
set in factory
0
Not adjustable
Not adjustable
Not adjustable
Not adjustable
45