Draining The System - Ariston microGENUS HE 24 MFFI Installation And Servicing Instructions

Type c boilers
Hide thumbs Also See for microGENUS HE 24 MFFI:
Table of Contents

Advertisement

3.8
D
RAINING THE
34
S
YSTEM
A
-
:
NTI
FROST DEVICE
The boiler is equipped with an anti-frost device which,
operates in two ways depending on the water temperature:
Temperature @ Flow Sensor below 8
The pump will run at speed 2 for 2 mins (1 minute in CH
and 1 minute in DHW).
After 2 minutes the PCB will check the temperature at the
Return Sensor, should the temperature be 8
the boiler will return to stand-by.
Should the temperature remain between 5
pump will continue to operate for a further 2 minutes, with
the diverter valve switching between CH and DHW as
before, this will continue for a maximum of 10 minutes,
after 10 minutes of this operation the burner will fire at
minumum power until the Retur n Sensor reads a
temperature of 33
o
C, there will then be 2 minutes of pump
over-run in the DHW circuit.
Temperature @ Flow Sensor below 5
The burner will fire at minimum power in CH until the
Return Sensor reads a temperature of 33
achieved there will be 2 minutes of pump over-run in the
DHW circuit.
N
: I
OTE
N THE EVENT OF FLAME FAILURE
5
C
O
IS BELOW
THE PUMP WILL OPERATE FOR
(1
CH
1
MIN
AND
MIN
This device only operates if the boiler is functioning
perfectly and:
- the system pressure is sufficient;
- the boiler is powered electrically;
- the gas is turned on.
P
/ D
V
P
UMP
IVERTER
ALVE
To prevent the pump and diverter valve from siezing the
boiler will activate the pump for 20 seconds every 21 hours
after it's last operation and activate the diverter valve once.
D
H
S
RAINING THE
EATING
YSTEM
The heating system must be drained as follows:
-
Turn off the boiler;
-
Attach a hose pipe and open the drain valve;
-
Drain the system at the lowest points (where present).
When the heating system is unused for an extended
period of time, it is recommended that you add
antifreeze with an ethylene glycol base to the water in
the heating pipe work and radiators if the ambient
temperature drops below 0°C during the winter.
This makes repeated draining of the entire system
unnecessary.
D
D
H
RAINING THE
OMESTIC
Whenever there is the danger of the temperature
dropping below the freezing point, the domestic hot
water system must be drained as follows:
-
Turn off the general water valve for the household
plumbing system;
-
Turn on all the hot water taps;
-
Empty the remaining water from the lowest points in
the system (where present).
o
C;
o
C or higher
o
C & 8
o
C;
o
,
AND THE TEMPERATURE
2
MINS
DHW).
:
ROTECTION
W
S
OT
ATER
YSTEM
o
C the
C, once