T
A
ABLE
6. Remove the pipe from the pressure gauge and connect screw "C" to the
pressure outlet in order to seal off the gas.
7. Carefully check the pressure outlets for gas leaks (valve inlet and outlet).
IMPORTANT!
Whenever you disassemble and reassemble the gas connections, always
check for leaks using an approved soap and water solution.
Gas restrictor
¿
0.91 Kg/h
1.22
-----
------ Kg/h
-----
20
28 mbar
8.3
22.9 mbar
----
---- mbar
6 x 0.77
6 x 1.30
0.90 Kg/h
------ Kg/h
2.9
2.9
37 mbar
29.5 mbar
---- mbar
6 x 0.77
9