Users Guide Installation and Servicing Instructions G.C. Number 47-116-30 G.C. Number 47-116-31 Manufacturered by Merloni TermoSanitari - Italy Country of destination: GB - IE Supplied By www.heating spares.co Tel. 0161 620 6677...
TABLE OF CONTENTS USERS GUIDE 1. GENERAL INFORMATION 2. OPERATING INSTRUCTIONS 3. BOILER SHUTDOWN SITUATIONS 4. TIME CLOCK INSTALLATION AND SERVICING INSTRUCTIONS 9. MAINTENANCE GENERAL INFORMATION 10. SERVICING INSTRUCTIONS 10.1 Replacement of Parts General Instructions 10.2 To Gain General Access Overall View 10.2.1 Removing the Front Panel 10.2.2 Removing the Sealed Chamber Front Panel...
USERS GUIDE 2. Operating Instructions 1. General Information This is a combined appliance for the production of central heat- Installation, start-up, adjustments and maintenance must be ing (C.H.) and domestic hot water (D.H.W.). This appliance must performed by a competent person only, in accordance with be used only for the purpose for which it is designed.
3. Boiler Shutdown Situations Winter and Summer Operating Modes The boiler is equipped with safety devices that intervene in cer- tain situations and shut it off. Most of these situations are commu- In the ‘winter’ operating mode, the boiler will produce both Central nicated by means of the L.E.D.s and at times the user may be Heating and Domestic Hot Water.
4. Time clock Technical Data Ambient temperature: - 10°C to + 55°C Running reserve: 150 h (not for 1.5 V DC) Shortest switching time: 15 minutes Programmable: Every 15 minutes UT011Ap Note: the time clock is for central heating control only. The clock is provided with a selector switch with three positions The time clock is provided with 96 switches, called riders, each of (see figure):...
INSTALLATION AND SERVICING INSTRUCTIONS 5. GENERAL INFORMATION General Instructions Check the following at least once a year: This manual is an integral and essential part of the product. It should be kept with the appliance so that it can be consulted by Check the seals for the water connections;...
General Information Overall View Legend: Flue connector Air intake for twin pipe flue systems Combustion chamber hood “Twin-pass” heat exchanger Domestic hot water temperature probe Combustion chamber Combustion chamber insulation panel Burner Detection electrode Ignition electrodes Gas valve Spark generator Low water pressure switch Safety valve (3 bar) Automatic By-pass...
INSTALLATION Siting the Appliance Reference Standards The technical information and instructions provided herein below although particular attention is drawn to the requirements of the are intended for the installer / Servicing Technician so that the current I.E.E. Wiring Regulations, and in Scotland, the electrical unit may be installed and serviced correctly and safely.