Boiler Operation; Important Notes - Alpha CD18S User Instructions

Wall mounted, fan assisted, room sealed, gas fired, high efficiency condensing system boiler
Hide thumbs Also See for Alpha CD18S:
Table of Contents

Advertisement

5

BOILER OPERATION

The operating sequence of the boiler is controlled by the selector switch on the control panel.
Setting the selector switch to position (2) the boiler will operate to provide central heating.
When the selector is set to central heating, it will respond to a demand for heat in the following sequence:-
a. The pump will start, the fan will operate and the main burner will light.
b. The output of the burner is automatically controlled to suit the system demand.
c. When the temperature of the system water in the boiler reaches that set by the thermostat or the room thermostat is
satisfied, the main burner is turned off and the fan stops after 50 seconds. The pump will continue to run to remove any
residual heat from the boiler.
6

IMPORTANT NOTES

1. BOILER LOCATION
Always ensure the following clearances are available around the casing of the boiler (not including the bottom tray):-
Top: 220 mm, Bottom: 250 mm, Each side: 5 mm, Front: 450 mm
Do not store any other articles in the cupboard containing the boiler and never place any clothing or combustible material on or near
the boiler or flue pipe.
2. FLUE TERMINAL
The terminal on the outside wall must not be allowed to be obstructed. If it is damaged, in any way, turn the boiler off and
contact your Service Engineer.
Note: The Alpha CD boilers are high efficiency condensing boilers and when operating vapour will be emitted from the
terminal. This is safe and quite normal.
3. MAINS FAILURE
In the event of an electrical supply failure the boiler will not operate. When the supply is restored, the boiler will return to normal
operation. Remember to reset the clock, if fitted, when the supply is restored.
4. CLEANING
Use only a damp cloth and mild detergent to clean the boiler outer casing. Do not use abrasive cleaners.
5. SERVICING
To maintain efficient and safe operation of your boiler, routine annual servicing is essential.
For advice on servicing contact:- The Alpha Helpline: 0870 3001964.
6. GAS LEAK
If a fault or gas leak is suspected, turn off the gas supply. Do not touch any electrical switches, do not smoke and extinguish all
naked flames. Contact your local Gas Region immediately.
7. ELECTRICAL SUPPLY
The boiler requires a 230/240 V ~ 50 Hz supply, fused at 3 A if a 13 A 3-pin plug is used or a 5 A fuse if any other type of plug is used.
To connect a plug:-
The colour of the wires in the mains lead of the boiler may not correspond with the coloured markings identifying the terminals
in your plug. In this case proceed as follows:-
The wire coloured green and yellow must be connected to the terminal in the plug that is marked with the letter E, or by the
earth symbol
, or coloured green or green and yellow.
The blue wire must be connected to the terminal which is marked with either the letter N or coloured black.
The brown wire must be connected to the terminal which is marked with the letter L or coloured red.
THE APPLIANCE MUST BE EARTHED.
Alpha CD18S/24S/30S
4