Viessmann VITOCROSSAL 200 Technical Data Manual page 14

Cm2 series gas-fired condensing boiler 1445 to 2245 mbh (423 to 658 kw)
Hide thumbs Also See for VITOCROSSAL 200:
Table of Contents

Advertisement

Specifications
System Design Considerations
Use ULC S-636 / UL 1738 certified venting systems for
category IV boilers. The following vent system suppliers
may be contacted for assistance in designing the
appropriate stainless steel venting system for Vitocrossal
200 CM2 boilers.
M&G / Duravent
Tel. 800-835-4429
Tel. 518-649-9700
Fax: 518-463-5271
Email: sales@duravent.com
Web: www.duravent.com
Selkirk Canada Corporation
375 Green Road
Stoney Creek, ON L8E 4A5
Tel.: (905) 662-6600
Fax: (905) 662-5352
(US) 1-800-992-8368
(Canada) 1-888-735-5475
Email: info@selkirkcorp.com
Web: www.selkirkchimney.com
Van-Packer Co. Inc.
302 Mill Street
PO Box 307
Buda, IL 61314
Tel.: (309) 895-2311
Fax: (309) 895-3891
1-888-877-8225
Email: vpstack@theramp.net
Web:www.vpstack.com
Enervex Inc. (formerly Exhausto)
Tel: 770-587-3238
Fax: 770-587-4731
(800) 225-2923
Email: info@exhausto.com
Web:www.vpstack.com
Wesmech Technical Sales
50 Ronson Drive, Suite 160
Toronto, ON M9W 1B3
Tel.: (416) 251-8990
Fax: (416) 251-8900
1-800-613-3789
Email: info@wesmechtech.com
Web: www.wesmechtech.com
Security Chimneys International Ltd.
2125 Rue Monterey, Laval, Quebec H7L 3T6
Tel. 450-973-9999
(US) 1-800-361-4909
(Canada) 1-800-667-3387
Fax: 450-973-2222
Email: infoeng@securitychimneys.com
Web: www.securitychimneys.com
14
Vitocrossal 200, CM2-400, -500 and -620 Technical Data
(continued)
Combustion air supply
The boiler must not be located in areas or rooms where
chemicals containing chlorine, bromine, fluorine, or other
corrosive chemicals are stored. Examples include bleach,
refrigerants, paint, paint thinner, hair spray, cleaning
solvents, water softener salt, etc. The combustion air
must not be contaminated with any amount of the above
mentioned chemicals.
Boiler should never be installed in areas where excessive
dust, high humidity, or risk of frost exist. Ensure adequate
ventilation and supply of fresh combustion air.
Consult your local Viessmann sales representative with
uncertainties in regard to a suitable boiler installation
location.
This boiler/burner unit needs clean fresh air for safe
operation. Provisions for combustion and ventilation air
must be made at time of installation. For gas or propane
installations, use the "Natural Gas Installation Code CAN/
CSA-B149.1 or B149.2" (Canada), or "National Fuel Gas
Code ANSI Z223.1" (USA), and/or provisions of local codes.
The sizing methods outlined in the aforementioned codes
should be used when installing a round duct to supply
combustion air from the outside.
System layout
The boiler water temperature limit is factory set to
167° F (75° C).
The boiler water temperature limit can be increased by
altering the adjustable high limit (AHL) to increase the
supply water temperature.
To minimize piping losses of the system, however,
Viessmann recommends that the radiation and domestic
hot water production in the system be designed for a
158° F (70° C) boiler supply water temperature.
Warranty
Our warranty does not cover damages resulting from
the following:
- Operation with contaminated fill and supplementary
feed water
- Operation with contaminated combustion air
- Exposing the boiler to pressures and temperatures
higher than its certified rating
See warranty sheet for details.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cm2-400Cm2-500Cm2-620

Table of Contents