H. PREPARATION FOR OPERATION/START-UP
The following items should be checked before attempting to operate the dryer:
1. Read ALL "CAUTION," "WARNING," and "DIRECTION" labels attached to the dryer.
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label.
3. GAS MODELS - check to ensure that the dryer is connected to the type of heat/gas indicated on the dryer
data label.
4. GAS MODELS - the sail switch damper assembly was installed and adjusted at the factory prior to
shipping. However, each sail switch adjustment must be checked to ensure that this important safety
control is functioning.
5. Check bolts, nuts, screws, terminals, and fittings for tightness and security.
6. GAS MODELS - be sure that ALL gas shutoff valves are in the open position.
7. Check that ALL back guard panels and service box covers have been replaced.
8. Check the lint drawer to ensure that it is closed and secured in place.
9. Rotate the basket (tumbler/drum) by hand to be sure it moves freely.
10. Check basket (tumbler) bearing setscrews to ensure that they are ALL tight.
11. Check that vent is connected to the dryer and is exhausted to the outdoors.
23