B. Service Diagnosis
• The appliance should be diagnosed and repaired only by qualified service
personnel to reduce the risk of death, electric shock, serious injury, or fire.
• Risk of electric shock. Use extreme caution and exercise safe electrical practices.
• Risk of electric shock. Control switch (KMS) in "OFF" position does not
de-energize all loads.
• Moving parts (e.g., fan blade) can crush and cut. Keep hands clear.
• CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are
securely in place after the appliance is serviced. Make sure that none have fallen
into the dispenser unit/ice storage bin.
• Make sure all food zones in the icemaker and dispenser unit/ice storage bin are
clean after service.
1. Diagnostic Procedure
The diagnostic procedure is a sequence check that allows you to diagnose the electrical
system and components. Before proceeding, check for correct installation, proper voltage
per nameplate, and adequate water supply.
Note: • When checking high voltage (115VAC), always choose a neutral (W) to establish
a good neutral connection.
• On 3-phase models, the neutral (W) is provided through MT. To confirm a good
neutral (W), check for 60VAC from neutral (W) to ground (GND). If 60VAC is
present, neutral (W) is good. If 60VAC is not present, check 208-230VAC main
power supply to MT. If 208-230VAC is present, check MT continuity.
• When checking voltage from the CB K1 connector (10 pin connector), pull CB
K1 connector out slightly to allow room for multimeter test leads contact.
1) Turn off the power supply, then access the control box. Clear any ice from BC.
2) Check that the 115VAC 10A fuses in the KMS and SRK are good.
WARNING