Download Print this page

GE AJHS08DCC Datasheet page 2

230/208 volt built-in heat pump

Advertisement

AJHS08DCC
Built-in RAC Installation
GE
230/208 Volt Built-In Heat Pump
®
Wall Case Dimensions and Installation Information (in inches)
Installation Information: A finished opening of 26-1/8" x 15-3/4"
clear of intrusions is required. Keep clearance of 4" from side
walls. Brick veneer or frame walls should have wood studding
surrounding case to provide firm anchoring with screws. Case
can be fastened directly to brick or block walls with screws sunk
in lead expansion shields.
Note: Units should be caulked on all four sides of case to the
building exterior to assure building integrity.
Two Wall Cases for Tenant Option Installation
When the air conditioner is offered as a tenant option, these
wall cases provide protection against outside elements.
RAB47 – includes wall case, exterior grille and steel
closure panels.
RAB48 – includes wall case, exterior grille, steel closure panel
and two layers of insulation.
Standard Wall Case RAB46
Solid-sided wall case fabricated of galvanized steel with
baked enamel finish. Welded areas are coated with a sealing
compound to help resist rust and corrosion. Polymer gasket
surrounds opening to assure tight weather seal. Aluminum grille
(RAG13) is included. Panels on interior and between case and
grille provide weather protection prior to installation of chassis.
Provide firm anchoring with screws. Case can be fastened
directly to brick or block walls with screws sunk in lead
expansion shields.
For answers to your Monogram,
GE
appliance questions, visit our website at
®
ge.com or call GE Answer Center
800.626.2000.
GE Profile
or
®
®
service,
Make frame if desired or caulk
Make frame if desired or caulk
between case and siding
between case and siding
26-1/8
26-1/8
Frame Construction
Frame Construction
15-3/4
26-1/8
26-1/8
Brick Block and Brick
Brick Block and Brick
Frame Construction
Frame Construction
Lintel
Lintel
OUTSIDE
OUTSIDE
16-7/8
16-7/8
Brick Block and Brick
Frame Construction
Lintel
OUTSIDE
15-3/4
15-3/4
Caulking
Drip Rail
Flexible Mounting Position
Lintel
Lintel
15-3/4
Fill open cells
Fill open cells
with mortar
with mortar
or insulation
or insulation
Plaster Line
Plaster Line
Trim Molding
Trim Molding
R
(if desired)
(if desired)
Specification Revised 6/07
INSIDE
INSIDE
Fill open cells
with mortar
or insulation
Plaster Line
Trim Molding
(if desired)
INSIDE
16-7/8
Total volume and shelf
Listed by
area are calculated by
Underwriters
the Association of Home
Laboratories
Appliance Manufacturers'
standards.