Water Filter Certifications - Viking Bottom-Mount Use & Care Manual

Professional freestanding french door bottom-mount refrigerator/freezer with dispenser
Table of Contents

Advertisement

Water Filter
Standard No. 42: Aesthetic Effects
Influent
USEPA
Influent
Parameter
Challenge
MCL
Average
Concentration
2.0 mg/L
Chlorine
1.88 mg/L
+ 10%
T & O
at least 10,000
57,000,000
Particulate**
particles/ml
#/ml
Standard No. 53: Health Effects
Influent
USEPA
Influent
Parameter
Challenge
MCL
Average
Concentration
Turbidity 1NTU** 11 + 1 NTU*** 10.7 NTU .031 NTU 0.49 NTU 97.09% 95.20%
99.5%
Minimum
166,500
Cysts
Red
50,000/L
#/L
107 108 fibers/
99%
L; fibers >10
Asbestos
155 MF/L <1 MF/L <1 MF/L >99.99% >99.99%
Red
micrometers in
length
Lead at
0.015
0.15 mg/L
0.153
pH 6.5
mg/L
+ 10%
mg/L
Lead at
0.015
0.15 mg/L
0.150
pH 8.5
mg/L
+ 10%
mg/L
Mercury at
0.002
0.06 mg/L
0.006
pH 6.5
mg/L
+ 10%
mg/L
Mercury at
0.002
0.06 mg/L
0.006
pH 8.5
mg/L
+ 10%
mg/L
0.003
0.09 mg/L
0.009
Atrazine
mg/L
+ 10%
mg/L
0.005
0.15 mg/L
0.014
Benzene
mg/L
+ 10%
mg/L
0.04
0.08 mg/L
0.081
Carbofuran
mg/L
+ 10%
mg/L
p-Dichlorob-
0.075
0.225 mg/L
0.208
enzene
mg/L
+ 10%
mg/L
0.0002
0.002 mg/L
0.002
Lindane
mg/L
+ 10%
mg/L
0.003
0.15 mg/L
0.015
Toxaphene
mg/L
+ 10%
mg/L
*Tested using a flow rate of 0.78 gpm; pressure of 60psig; pH of 7.5 + 0.5; temp of
68˚ + 5˚F (20˚ + 3˚C).
**Measurement in Particles/ml. Particles used were 0.5 - 1 microns
***NTU - Nephelometric Turbidity Units
Effluent
% Reduction
Required
Avg.
Max.
Avg.
Min.
Reduction
<0.051363
0.06
%
>97.26% 96.84
mg/L
mg/L
30,583
69,000
99.52% 98.94%
#/ml
#/ml
Effluent
% Reduction
Required
Avg.
Max.
Avg.
Min.
Reduction
0.5NTU
L <1 #/L
<1 #/L >99.99% >99.99% >99.95%
<0.001
<0.001
>99.35% >99.29% 0.10 mg/L
mg/L
mg/L
<0.001
<0.001
>99.33% >99.29% 0.10 mg/L
mg/L
mg/L
<0.003
<0.005
0.002
95.70% 90.91%
mg/L
mg/L
mg/L
<0.008
<0.015
0.002
86.22% 75.93%
mg/L
mg/L
mg/L
<0.002
<0.002
0.003
76.99% 75.31%
mg/L
mg/L
mg/L
<0.006
<0.011
0.005
95.71% 92.14%
mg/L
mg/L
mg/L
<0.001
<0.001
98.74% 98.46% 0.04 mg/L
mg/L
mg/L
<0.005
<0.005
0.075
99.76% 99.74%
mg/L
mg/L
mg/L
<0.000
<0.001
0.0002
98.72% 96.50%
mg/L
mg/L
mg/L
<0.001
<0.001
0.003
92.97% 91.67%
mg/L
mg/L
mg/L
22

Water Filter Certifications

Min.
50%
Trademark /Model Designation
RWFFR-750
85%
Manufacturer: CUNO, Incorporated, a 3M Company
The water treatment device(s) listed on this certificate have met the testing requirements
pursuant to Section 116830 of the Health and Safety Code for the following health related
Min.
contaminants:
Microbiological Contaminants and Turbidity
Cysts
Turbidity
Organic Contaminants
Atrazine
Lindane
99%
Benzene
Carbofuran
p-dichlorobenzene
Toxaphene
Rated Service Capacity: 750 gal.
Do not use with water that is microbiologically unsafe or with water of unknown quality
without adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected waters that may contain filterable cysts.
State of California
Department of Health Services
Water Treatment Device
Certificate Number
06 - 1790
Date Issued: June 1, 2006
Replacement Elements
RWFFR
Inorganic/Radiological Contaminants
Asbestos
Lead
Mercury
Rated Service Flow: 0.78 gpm