. . . . . . . . . . .2
Operating Instructions
Air Direction . . . . . . . . . . . . . . . .4
Auxiliary Controls . . . . . . . . . .5-9
Controls . . . . . . . . . . . . . . . . . . . .3
Vent Control . . . . . . . . . . . . . . . .4
Air Filters . . . . . . . . . . . . . . . . . .11
Base Pan . . . . . . . . . . . . . . . . . .10
Outdoor Coils . . . . . . . . . . . . . .10
Room Cabinet and Case . . . . . .10
Electrical Supply . . . . . . . . .14-16
Optional Drain Kit . . . . . . . . . .19
Preparation . . . . . . . . . . . . . . . .12
Consumer Support
Consumer Support . . .Back Cover
Product Registration . . . . . .25, 26
Warranty . . . . . . . . . . . . . . . . . .27
Write the model and serial
numbers here:
Model # ____________________
Serial # ____________________
Find these numbers on a label
behind the room cabinet on the
base pan.
. . . . . . .20
Owner's Manual and
Installation Instructions
Heat/Cool Model 2500
Heat Pump Model 3500
49-7415-2 JR 06-01

Advertisement

Table of Contents
loading

Summary of Contents for GE Zoneline 2500

  • Page 1: Table Of Contents

    Write the model and serial numbers here: Model # ____________________ Serial # ____________________ Find these numbers on a label behind the room cabinet on the base pan. Owner’s Manual and Installation Instructions Heat/Cool Model 2500 Heat Pump Model 3500 49-7415-2 JR 06-01...
  • Page 2: Safety Instructions

    IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. SAFETY PRECAUTIONS This Zoneline must be properly installed in accordance with the...
  • Page 3: Controls

    Turn the knob to WARMER (red) and the indoor air will become warmer. 3500 Series only When the outdoor temperature is lower than 25°F, heat is provided by the electric heater in the air conditioner instead of by the heat pump.
  • Page 4: Air Direction

    Other features your Zoneline may have. Ventilation Control The ventilation control lever is located at the upper left side of the Zoneline unit, behind the room cabinet. NOTE: The vent door shipping hardware must be removed before using the vent control lever. See the Installation Instructions in this manual.
  • Page 5: Auxiliary Controls

    Auxiliary Controls on your Zoneline. Auxiliary Controls – Dip Switches The auxiliary dip switch controls are located behind the room cabinet, through an opening in the control panel. Remove the room cabinet. See the To Remove the Room Cabinet section. The factory settings will be in the DOWN position.
  • Page 6 Auxiliary controls on your Zoneline. Remote Thermostat–Class 2 When this switch is enabled (UP) , it allows the unit to operate off of a Class 2 Remote Control Wall Thermostat. The unit controls are disabled. Load Shedding (CDC) This feature is active only if the unit is in CDC mode.
  • Page 7 Temperature Limiting Temperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating. Temperature limiting is controlled by the second six auxiliary switches. DOWN TL1 (C) (Temp.
  • Page 8 Auxiliary controls on your Zoneline. Auxiliary Controls–Terminal Connections The auxiliary controls are located behind the room cabinet beneath the control panel. Remove the room cabinet. See the To Remove the Room Cabinet section. Remove the screw from the control panel corner.
  • Page 9 Door Sensor (Obtained locally) When connected, the door sensor will detect when the door in the room was opened or closed. This feature must be used in conjunction with the motion sensor. The door and motion sensors work together to automatically turn the unit ON or OFF. External Fan (Obtained locally) When connected, an auxiliary or external fan can be controlled with the indoor fan motor...
  • Page 10: Care And Cleaning

    If they are clogged with dirt or soot, they may be professionally steam cleaned, a service available through your GE service outlet. You will need to remove the unit to inspect the coils because the dirt build-up occurs on the inside.
  • Page 11: Air Filters

    Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care www.GEAppliances.com 2 Air filters Do not operate the ®...
  • Page 12: Preparation

    Installation Instructions Questions? Call 800.GE.CARES (800.432.2737) BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT – • instructions for local inspector’s use. IMPORTANT – • governing codes and ordinances. Note to Installer – • Be sure to leave these instructions with the owner.
  • Page 13: Installation Instructions

    REPLACING AN EXISTING UNIT? Use the correct wall case This unit is designed to be installed in a GE plastic or insulated metal wall case. This minimizes condensation from forming on the room side of the case. If the current wall case is not insulated, you can reduce...
  • Page 14: Electrical Supply

    It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes. Large Tandem 30 Amp. Branch Circuit and Proper GE Unit Amperage Rating Subbase Kit 15/20 RAK204D20 RAK204D30...
  • Page 15 This will help when the box is being reinstalled. The cord will be coiled up inside the junction box. Proper GE Subbase Kit RAK204E15 RAK204E20...
  • Page 16 265 VOLT ELECTRICAL SUPPLY NOTE: Order Kit RAK4002CW to enable a quick disconnect inside the junction box. ATTACH CONDUIT 1 Use the round knockout at the bottom of the junction box to attach conduit coming from the branch circuit. Remove the knockout, attach the conduit and bring wires into the junction box.
  • Page 17: Installing The Zoneline

    • Install the exterior grille from the room side following instructions packed with the grill. Insulated Wall Case This unit is designed to be installed in a GE plastic or an insulated steel wall case. This minimizes condensation from forming on the room side of the case.
  • Page 18 INSTALL THE UNIT INTO THE WALL CASE Slide the unit into the wall case and secure with four screws through the unit flange holes. Installation Instructions REPLACE THE ROOM CABINET Reinstall the room cabinet by hooking the top over the rail along the unit top (1), then pushing it in at the bottom (2).
  • Page 19: Optional Drain Kit

    OPTIONAL – DRAIN KIT INSTALLATION Dry Air 2500 Series models are designed to improve dehumidification by 25%. Since more moisture will be removed from the air, there is a greater possibility that water will drip from the wall case than with a standard unit. To prevent this water from dripping onto external building walls, we recommend the use of RAD10 Drain Kit.
  • Page 20: Troubleshooting Tips

    • Outdoor grille must have a minimum of 65% free area. Non-GE grilles may be too restrictive for proper performance. Consult your salesperson for assistance. • Turn the control to a lower or higher setting.
  • Page 21: Normal Operating Sounds

    Things that are normal. www.GEAppliances.com Normal Operating Sounds You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • Page 22 Notes.
  • Page 23 Notes.
  • Page 24 Notes.
  • Page 25: Product Registration

    Cut here Please place in envelope and mail to: General Electric Company Warranty Registration Department P.O. Box 32150 Louisville, KY 40232-2150...
  • Page 26: Serial Number

    Month * Please provide your e-mail address to receive, via e-mail, discounts, special offers and other important communications from GE Appliances (GEA). Check here if you do not want to receive communications from GEA’s carefully selected partners. General Electric Company Louisville, Kentucky www.GEAppliances.com...
  • Page 27: Warranty

    Any part of the Zoneline which fails due to a defect in materials or workmanship. During this From the date of the full one-year warranty, GE will also provide, free of charge, all labor and on-site service to original purchase replace the defective part.
  • Page 28: Consumer Support

    Caution must be exercised, since improper servicing may cause unsafe operation. Contact Us If you are not satisfied with the service you receive from GE, contact us on our Website with all the details including your phone number, or write to: General Manager, Customer Relations Register Your Appliance Register your new appliance on-line—at your convenience! Timely product registration will allow for...