Download Print this page

Cabinet Installation - Viking VMOS200 Installation Manual

Microwave built-in trim kit
Hide thumbs Also See for VMOS200:

Advertisement

CABINET OR WALL CUTOUT
Cutout Dimensions
Height (A)
Minimum
16 3/4" (42.5 cm)
Maximum
17" (43.2 cm)
Width (B)
Minimum
24 3/8" (61.9 cm)
Maximum
24 11/16" (62.7 cm)
Depth (C)
Minimum
20" (50.8 cm)
ELECTRICAL OUTLET LOCATION
Outlet should NOT be in the shaded area as
indicated on Illustration 1
NOTE 1: If the Depth (C) dimension is greater
than 21" (53.3 cm), the outlet location may be in
any area on the rear wall.
NOTE 2: The floor of the opening should be
constructed of plywood strong enough to support
the weight of the oven and floor load
(approximately 100 pounds). The floor should be
level for proper operation of the oven. Be sure to
check the local building code as it may require that
the opening be enclosed with side, ceiling and rear
partition. The proper functioning of the oven does
not require the enclosure.
EXHAUST DUCT ASSEMBLY
1. Place the Exhaust Duct in the opening.
When the Exhaust Duct Assembly is in the
opening correctly, the flanges will be tightly
against the lower edge of the opening. See
Illustration 2.
2. Secure the Exhaust Duct Assembly with the
two (1/2") screws A. IMPORTANT:
Secure
screws in outer hole.
Detail A
Screw A
6"
(15.2 cm)
4"
(10.2 cm)
4"
(10.2 cm)
Illustration 1
Illustration 2
Flanges
Exhaust Duct Assembly
4

CABINET INSTALLATION

1. Place the oven adjacent to the wall or cabinet opening. Plug the power cord into the electrical outlet.
2. Carefully guide the assembled oven into the prepared opening. Slide the oven on the Exhaust Duct Assembly. See
Illustration 3. Avoid pinching the cord between the oven and the wall. Adjust the position of the oven so that the
feet of the oven are fitted into the recesses of the Exhaust Duct Assembly. See Illustration 4.
Illustration 3
FRAME INSTALLATION
VMTK ONLY
Position the FRAME ASSEMBLY to be square with the oven. Carefully place the FRAME ASSEMBLY on the oven.
Check that it is level and then secure with two SCREWS B. See Illustration 5. Secure the bottom portion of the FRAME
ASSEMBLY with the two remaining SCREWS B. See Illustration 5.
Illustration 5
Screw B
Screw B
Illustration 4
OVEN
SIDE
Exhaust Duct Assembly
Screw B
Screw B
5
Foot
Recess