10. A newgasket s hould beusedin allcases to prevent a
possible water l eak. ( SeeElement Gasket inthe"Repair
Parts List"Chart). Place thenewelement gasket o nthe
thread sideofthecleaned or new element andscrew into
tank, s ecuring tightly u sing anelement wrench.
FIGURE
36.
11. Close the water
heater
drain valve
by turning
the handle
to
the right (clockwise).
12. Open the cold water
supply
valve to the water
heater.
NOTE:
The cold
water
supply
valve
must
be left open
when
the water
heater
is in use.
13. To insure
complete
filling
of the tank,
allow
air to exit by
opening
the nearest
hot water faucet. Allow water to run until
a constant
flow is obtained.
This will let air out of the water
heater
and the piping.
improper
installation
and use may result
in property
damage.
• Fill tank with water
before operation.
Never
use this water
heater
unless
it is completely
full of water.
To prevent
damage
to the tank and heating
element,
the tank
must
be filled
with water.
Water
must flow
from the hot water
faucet
before
turning
"ON" power.
14. Check
element
for water
leaks.
If leakage
occurs,
tighten
element
or repeat
steps
2 and 3, remove
element
and
reposition
gasket.
Then
repeat steps
10 through
14.
15. Reconnect
the two wires
to the element
and then check
to
make sure the thermostat
remains
firmly against
the surface
of the tank.
16. Replace
terminal
cover on thermostat
making
sure that the
locking
tabs on the terminal
cover are in place.
FIGURE 38.
17. Place the insulation
block back in place so that it completely
covers
the thermostat
and element.
FIGURE 39.
18. Replace
access
panel.
19. Turn "ON" electric
power to water
heater.
FIGURE 37.
2O
FIGURE 40.

Advertisement

Table of Contents
loading