RclVWin
Syntax: RclVWin {<variable name> ; <folder name\
file name>}
Function: Recalls View Window values, which were
previously saved under the specified name.
Description: A folder path can be specified only up to
one level.
Receive38k
Syntax: Receive38k <variable name>
Function: Receives EA-200 data.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
• For details about using this command, see the user
documentation that comes with the EA-200.
• Note that you need to replace all instances of the
Receive command in the examples provided in
the EA-200 user documentation with the command
Receive38k. You should also adjust the other
commands in the EA-200 examples so they conform
to the ClassPad command syntax and usage as
described in this manual.
Rename
Syntax: Rename <current variable name>, <new
variable name>
Function: Renames a variable.
Return
Syntax: Return {<variable>}
Function 1 (Main Program): Terminates program
execution.
Function 2 (Subroutine Program): Returns from a
subroutine.
Tip
• The Return command can be executed during an If, For,
Do, While, or Switch process.
• Appending a <variable> to the Return command in
the Main application and executing the command will
cause the variable to be displayed when the program is
complete.
S
Scatter
Function: Used as a StatGraph command argument
to specify an option. See StatGraph.
Misc - Graph&Table(2)
I/O - Communication
Misc - Variable
Ctrl - Control
Misc - Statistics(1) - Graph
Send38k
Syntax: Send38k <variable name>
Function: Sends EA-200 data.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
• For details about using this command, see the user
documentation that comes with the EA-200.
• Note that you need to replace all instances of the
Send command in the examples provided in the
EA-200 user documentation with the command
Send38k. You should also adjust the other
commands in the EA-200 examples so they conform
to the ClassPad command syntax and usage as
described in this manual.
• <variable name> must be a variable that contains
a real number or a list. Anything else results in an
error.
SendVar38k
Syntax: SendVar38k <variable name>
Function: Sends variable names and variable
contents.
Description:
• The OpenComPort38k command must be executed
before this command is executed.
• The CloseComPort38k command must be
executed after this command is executed.
SeqSelOff
Syntax: SeqSelOff {
E ;
E ;
E}
Function: Deselects the specified sequence
expression. Specifying " E", " E", or " E" as the
argument activates [Explicit]. Specifying any other
argument activates [Recursive].
SeqSelOn
Syntax: SeqSelOn {
E ;
E ;
E}
Function: Selects the specified sequence expression.
Specifying " E", " E", or " E" as the argument
activates [Explicit]. Specifying any other argument
activates [Recursive].
SeqType
Syntax: SeqType {" " ; "
"
"}
+2 1
Function: Specifies the recursion type.
Description: Specifying " " as the argument activates
[Explicit]. Specifying any other argument activates
[Recursive].
Chapter 12: Program Application
Chapter 12: Program Application
I/O - Communication
I/O - Communication
Misc - Sequence
;
;
;
;
+1
+2
+1
+2
+1
Misc - Sequence
;
;
;
;
+1
+2
+1
+2
+1
Misc - Sequence
" ; "
" ; "
+1 0
+1 1
+2 0
;
;
+2
;
;
+2
" ;
211
211

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Classpad ii

Table of Contents