Installation Manual of Room Air Conditioner
Preparation
Necessary Tools for Installation
Hammer
Nipper
Hacksaw
Hole core drill
Spanner wrench(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
All wiring to the unit must be in accordance with the National Electric code
and local ordinances.
Drawing for the installation of indoor and outdoor units
The models use HFC free refrigerant R410A
more than 15 cm
(6 in.)
more than10cm
(4 in.)
Indoor unit B
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
The marks from
to
A
in the gure are the
G
Part Numbers.
The distance between
the indoor unit and the
oor should be more
than 6 ft.
The above picture is for reference only. Your product may look different.
Read this manual before installation
Explain the operation of the unit to the user according to this manual
NO.0010564641
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
Indoor unit A
more than 10cm
more than 20cm
(8 in.)
more than 20cm
(8 in.)
more than 60cm
(24 in.)
Selection of Installation Place
Indoor Unit - Select a location that is
Robust not causing vibration, where the unit can be supported satisfactorily.
Not affected by heat or steam generated in the vicinity, and where the inlet and outlet of
the unit are not disturbed.
Possible to drain easily, and where piping can be connected with the outdoor unit.
Where conditioned air can be spread in a room evenly.
Place where the distance of more than 3 ft from televisions, radios, wireless apparatuses
and uorescent lamps 3 feet or approximately.
In the case of xing the remote controller on a wall, place where the indoor unit can
receive signals when the uorescent lamps in the room are in use.
Outdoor Unit - Select a location that is
Strong enough base to bear the unit, where vibration and noise are not increased.
That is easily accessible for maintenance or service.
A distance marked
is available as illustrated in the below gure.
Attention must be paid to
the downward angle up
of drain hose
F
(4 in.)
C
D
E
more than 15cm
(6 in.)
Installation
tilated.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Insulating material
G
Piping hole cover
Floor xing dimensions of the outdoor unit
(Unit:mm / inch)
X
Y
Dimensions(mm/inches)
Model
x
y
113.5
583
HSU218VHG-W
(4 1/2)
(23)
Fixing of outdoor unit
Fix the unit to concrete or block with bolts
(2/5 in. ) securely.
When tting the unit to wall surface, roof or
rooftop, x the unit securely in consideration
of earthquake and strong wind.
If vibration may affect the house, x the unit
by attaching a vibration-proof mat.
Domestic Air Conditioner
Z
X
z
319.5
(12 5/8)