Leakage Checkpoints - Kenmore 153.338071 Owner's Manual

Commercial gas water heater 74/98 gallon (280/371 liter)
Table of Contents

Advertisement

Operationa_
Conditions
(Continued)
Leakage
Checkpoints
©
FIGURE27.
Read and understand
instruction
manual
and
safety
messages
before
installing,
operating
or
servicing
this water heater,
Failure to follow instructions
and
safety' messages
could result
in
death or sedous
injury
Instruction
ManuaU must remain
with water heater
Read this manual first. Then before checking the water heater
make sure the gas supply has been turned "OFF", and never
turn the gas "ON" before the tank is completely full of water.
Never use this water heater unless it is completely
filled with
water.
To prevent damage to the tank, the tank must be filled
with water. Water must ftow from the hot water faucet before
turning "ON" gas to the water heater, see Figure 27.
/% Water at the draft hood is water vapor which has condensed
out of the combustion products. This is caused by a problem
in the vent. Contact the gas utility.
B. *Condensation
may be seen on pipes in humid weather or
pipe connections
may be leaking.
C. *The anode rod fitting may be leaking.
D. Small amounts of water from temperature-pressure
relief
valve may be due to thermaI
expansion
or high water
pressure in your area.
E. *The temperature-pressure
relief valve may be leaking at
the tank fitting.
R Water from a drain valve may be due to the valve being
slightly opened.
G. *The drain valve may be leaking at the tank fitting.
H.
Combustion
products
contain
water
vapor
which
can
condense on the cooler surfaces of the tank. Droplets form
and drip onto the burner or run on the floor. This is common
at the time of start-up after installation and when incoming
water is cold.
Water in the water heater bottom or on the floor may be from
condensation,
loose connections,
or the relief
vaIve.
DO NOT replace the water heater until a full inspection of all
possible water sources is made and necessary
corrective
steps taken.
Leakage from other appliances, water lines, or ground seepage
should also be checked.
To check where threaded portion enters tank, insert cotton
swab between iacket opening and fitting. If cotton is wet,
follow "Draining" instructions in the Service and Adjustment
section and then remove fitting. Put pipe dope or teflon tape
on the threads and replace. Then follow FT!/ing the Water
Heater instructions
in the instattation instructions
section.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

153.338001

Table of Contents