Customer Responsibilities; Product Specifications - Kenmore 153.338071 Owner's Manual

Commercial gas water heater 74/98 gallon (280/371 liter)
Table of Contents

Advertisement

Thank You for purchasing
a Kenmore water heater. Properly
installed
and maintained,
it should give you years of trouble
free service. If you should decide that you want the new water
heater professionally installed by Sears call 1-800-4+MY-HOME ®-
They will arrange
for prompt,
quality
installation
by Sears
authorized
contractors.
Abbreviations
Found tn This instruction
Manuam:
,'
UL - Underwriter's
Laboratories
+
CSA - Canadian Standards Association
+
ANSI - American National Standards
Institute
,,
NFPA - National Fire Protection Association
,,
ASME - American Society of Mechanical Engineers
+
GAMA - Gas Appliance Manufacturers
Association
+
EPACT- Energy PolicyAct
This gas-fired
water
heater
is design
certified
by UL
Underwriter's
Laboratories
under
American
National
Standard/CSA
Standard
for Gas Water
Heaters
ANSI
Z21.10.3 + CSA 4.3 (current edition).
Read the "Safety Precautions" section, page 3 of this manual
first and then the entire manual carefully. If you don't follow
the safety rules, the water heater will not operate properly. It
could cause DEATH, SERIOUS
BODILY INJURY AND/OR
PROPERTY DAMAGE.
This manual
contains
instructions
for the installation,
operation, and maintenance
of the gas-fired water heater. It
also contains warnings through out the manual that you must
+
read and be aware of. All warnings and aiI instructions are
essential
to the proper operation
of the water heater and
your safety. Since we cannot put everything on the first few
pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING
+
TO +NSTALL OR OPERATE THE WATER HEATER,
The installation
must conform with these instructions
and
the local code authority having jurisdiction.
In the absence of
local codes, installatlons
shall comply with the following:
tn the United States:
The National
Fuel Gas Code ANSI
Z223.1/NFPA
54.
This publication
is available
from the
Canadian Standards Association,
8501 East Pleasant Valley
Rd, Cleveland
Ohio 44131, or The National Fire Protection
Association, 1 Batterymarch
Park, Quincy, MA 02269.
If after reading this manual you have any questions or do not
understand
any portion of the instructions,
calI the Sears
Service Center.
Carefully plan the place where you are going to put the water
heater.
Correct
combustion,
vent action,
and vent pipe
installation
are very important
in preventing
death from
possible
carbon
monoxide
poisoning
and fires.
See
figures 1 and 8 through 13.
Examine the location to ensure the water heater complies
with the Facts to Consider About the Location section in this
manual.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake.
See
instructions
for correct
installation
procedures.
Instructions
may be obtained from your local
dealer,
wholesaler, public utilities or California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
Massachusetts
Code
requires
this water
heater
to be
installed in accordance
with Massachusetts
248-CMR 2.00:
State Plumbing Code and 248-CMR 5.00.
Complies with SCAQMD
rule #1146.2 and districts having
equivalent
NOx requirements.
RECOVERY
MmNIM UM
B_MENSmONS
TANK
TYPE
RATE GALS+
VENT PIPE
BmAMETER
IN INCHES (rnm)
MODEL
CAPACmTY
OF
BTU
PERHOUR
INCHES
raNCHES
HEmGBTTO
NUMBER
iN GALS (LTRS)
GAS
RATE
@ 100°F RISE
(rnm)
(rnm)
JACKET TOP
153.338071
74 (280)
NATURAL
75,100
72.8
4" (102)
26 1/2" (673)
61 1/8" (1,553)
153.338001
98 (371)
NATURAL
75,100
72.8
4" (102)
28 1/2" (873)
69 3/4" (1,772)