Water
Piping (cont'd)
• Look at the top cover of the water heater. The water outlet is
marked hot. Put two or three turns of teflon tape around
the
threaded
end of the threaded-to-sweat
coupling
and around
both ends of the ¾ threaded
nipple.
Using flexible connec-
tors, connect the hot water pipe to the hot water outlet of the
water heater.
• Look at the lower right side of the water heater. The
cold
water inlet is marked
cold. Put two or three turns of teflon
tape around
the threaded
end of the threaded-to-sweat
cou-
pling and around
both ends of the ¾" threaded
nipple. Using
exible connectors,
connect
the cold water pipe to the cold
water inlet of the water heater.
WATER
PIPING
PRESSURE
TEST
This section is only for the mobile home manufacturer
installing
the water heater when the installation
is to comply with H.U.D.
Standards.
Wh,,en testing the water ways, H.U.D.
Standards
state:
Water distribution
system. All water piping in the water dis-
tribution
system shall be subjected
to a pressure test. The test
shall be made by subjecting
the system to air or water at 100
psi for 15 minutes
without
loss of pressure. When
air pres-
sure is used, she water heater
shall not be connected
dur-
ing the test."
NOTE: This water heater is insulated to minimize heat loss
from the tank. Further reduction in heat loss can be accom-
plished by insulating the hot water lines from the water
_l.t
er.
INSTALLATION
GOMPLETED
USING
SEARS INSTALLATION
KIT
AWARNING
If the water piping system is to be air pressure test-
ed, the water
heater must be disconnected
from
the water
piping system. Failure to disconnect the
water
heater
during air pressure testing
of the
water piping system could result IN DEATH,
SERI-
OUS BODILY INJURY, OR PROPERTY DAMAGE.
HOT OUTLET
HOT OUTLET
TO HOUSE
CONNECTOR
THREADED
TO
SWEAT
COUPLING
3/4"THREADED
COUPLINGS
PRESSURE
RELIEF VALVE
THREADED
TO
SWEAT
COUPLING
SHUTOFF
VALVE
COLD INLET
WATER LINE
(Do not cap or plug.
Must terminate
beneath
Mobile
Home)
WHEN
AIR TESTING,
:
REMOVE THE WATER
LINES FROM THE
WATER HEATER
COLD INLET