36" stainless steel glass canopy wall-mount hood

Advertisement

Glass Canopy Wall-Mount Hood Specifications
Product Shipping Weight (approx.) – 54 Lbs.
Wall-Mount Installation
Ventilation system is preset to exhaust air outside. If outside
ducting is not possible, optional Duct-Free Recirculation Kit
(PN # FHWRKT60LS) is available to convert ventilation to allow air
to recirculate inside. (Refer to Ducted Option Specifications for
outside ventilation.)
Sones Rating – 6.5
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = 0.516 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Amps @ 120 Volts = 4 Amps
Always consult local and national electric codes. Check local building
codes for installation requirements, as they may vary per locale.
Minimum installation height allowed from bottom of hood to standard
36"-high electric or gas cooking surface is 26" - 35". (NOT more than
32" recommended.) For detailed instructions regarding install heights
in 8', 9' and 10' ceiling applications, refer to installation guide on web.
To prepare mounting surface, adequate structure and support must
be provided, capable of supporting 100 lbs.
USA
10200 David Taylor Drive
Charlotte, NC 28262
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
FHWC3660L 02/12
Glass Canopy Wall-Mount Hood
Ducted Option Specifications
Note: For planning purposes only. Refer to Product Installation Guide
Optional Accessories
1-800-FRIGIDAIRE
frigidaire.com
1-800-265-8352
frigidaire.ca
© 2012 Electrolux Home Products, Inc.
For outside ventilation.
Exhaust Duct Required – 6" round
For most efficient airflow exhaust, use a straight run or as few elbows
as possible.
Use metallic flex ducting only to connect rigid duct directly to
transitions (if allowed by code).
Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.
Cold weather installations should have additional backdraft damper
installed.
Refer to installation instructions on web for detailed exhaust duct
preparation and converting vent blower system for recirculating inside.
on the web at frigidaire.com for detailed instructions.
Duct-Free Recirculation Kit – (PN # FHWRKT60LS).
10' Flue Extension Kit – (PN # FHW10X60LS).
Accessories information available
on the web at frigidaire.com
FHWC3660L S
36" Stainless Steel
Specifications
subject to change.