General Instructions THIS BOOKLET CONTAINS INFORMATION ON: RGSSFP Table of Contents The RGSSFP is a food prep case with refrigerated self- General Instructions ..........2 service merchandising in the front, and hot and/or cold Cut & Plan Views ............3 food prep area on top.
The serial number and shipping date of all equipment has constant and proper temperature. This means that from been recorded in Hussmann’s files for warranty and re- the time the product is received, through storage, prepa- placement part purposes. All correspondence pertaining...
IGFP-RGSSFP-0008 INSTALLING CONDENSATE DRAIN REFRIGERATION LINES LIQUID SUCTION Poorly or improperly installed condensate drains can se- riously interfere with the operation of this refrigerator, 3/8" O.D. 5/8" O.D. and result in costly maintenance and product losses. Please NOTE: The standard coil is piped at 5/8" (suction); however,...
Rev.0008 EXPANSION VALVE ADJUSTMENT Electrical Expansion valves must be adjusted to fully feed the evapo- WIRING COLOR CODE rator. Before attempting any adjustments, make sure the Self Contained cases are wired using a terminal block. evaporator is either clear or very lightly covered with frost, Remote cases are wired as follows: and that the fixture is within 10 F of its expected operat- S TA N DA R D C A S E W I R E C O L O R C O D E...
3. Product should be worked and rotated on a regular Hussmann cases were not designed to “heat up” or “cool basis, not to exceed a 4-hour period. down” product—but rather to maintain an item’s proper 4.
Rev.0008 Ammonia. • When cleaning the inside of the cases, we recom- Soap and hot water are not enough to kill this bacteria. A mend that the glass be fully opened and covered to sanitizing solution must be included with each cleaning pro- prevent solutions from splashing onto the glass and cess to eliminate this bacteria.
TOWARD THE MOTOR. COPPER COILS The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers. Hussmann recommends using #15 Sil-Fos for repairs.
Rev.0008 Appendices APPENDIX A. – Temperature Guidlines insulated according to the manufacturer’s recommendations. 1.3 A clogged waste outlet blocks refrigeration. The installer is The refrigerators should be operated according to the manufacturer’s responsible for the proper installation of the system which published engineering specifications for entering air temperatures for dispenses condensate waste through an air gap into the building specific equipment applications.
IGFP-RGSSFP-0008 only in Fahrenheit shall be accurate to 2 F. The thermometer manufacturer? Is the refrigerator charged with the proper should be checked for proper calibration. (It should read 32 F refrigerant and lubricant? Does the system use the recommended when the stem is immersed in an ice water bath).
Page 17
On Hussmann refrigeration systems, an additional (4) year extended warranty for the motor/compressor assembly is available, but must be purchased prior to shipment to be in effect. Hussmann reserves the right to inspect the job site, installation and reason for failure.
IGFP-RGSSFP-0008 Service Record Last service date: /Chino The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit. Additional copies of this publication may be obtained by contacting: They can be found on a small metal plate on the unit.
Need help?
Do you have a question about the RGSSFP and is the answer not in the manual?
Questions and answers