Crown CTs 600 Operation Manual page 14

Cts 2-channel series commercial audio power amplifiers
Table of Contents

Advertisement

8 AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Data based on all channels driven.
Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Line current figures for 100VAC units (not shown) are 1.2 times the line current figures of 120VAC units.
Power draw ("watts in") of 100VAC units is the same as power draw of 120VAC units.
Rated
Load
Power
At Idle (sleep mode)
1/8th Power Pink Noise
8 Ohms/Ch.
1000x2
16 Ohms Bridge
2000
Typical of program material
4 Ohms/Ch.
1000x2
just at clip.
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch.
1000x2
140/200V Bridge 2000
1/3rd Power Pink Noise
8 Ohms/Ch.
1000x2
16 Ohms Bridge
2000
Typical of program material
4 Ohms/Ch.
1000x2
with severe clipping.
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
4 Ohms Bridge
2000
70/100V/Ch.
1000x2
140/200V Bridge 2000
page 26
CTs 2000
Line Current
Line Current
Watts
Thermal Dissipation
120VAC
230VAC
watts in
watts out
dissapated
Btu/hr
40
0
40
137
6.6
3.3
546
256
290
988
7.0
3.5
563
255
307
1049
7.2
3.6
602
251
351
1198
6.7
3.4
639
257
382
1304
11.3
5.6
980
676
304
1036
12.3
6.2
1064
672
392
1338
13.7
6.9
1190
705
485
1655
11.6
5.8
990
674
316
1080
CTs Power Amplifiers
CTs Power Amplifiers
8 AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Measurements made with 120VAC mains. Data based on all channels driven.
Line current figures for 230VAC units derived by multiplying 120VAC figures by 0.5.
Line current figures for 100VAC units (not shown) are 1.2 times the line current figures of 120VAC units.
Power draw ("watts in") of 100VAC units is the same as power draw of 120VAC units.
kcal/hr
34
At Idle (sleep mode)
1/8th Power Pink Noise
249
Typical of program material
just at clip.
264
302
329
1/3rd Power Pink Noise
261
Typical of program material
with severe clipping.
337
417
272
Operation Manual
Operation Manual
CTs 3000
Rated
Line Current
Line Current
Load
Power
120VAC
230VAC
watts in
40
8 Ohms/Ch.
1000x2
7.2
3.6
579
16 Ohms Bridge
2000
4 Ohms/Ch.
1000x2
8.5
4.2
697
8 Ohms Bridge
2000
2 Ohms/Ch.
1000x2
9.6
4.8
790
4 Ohms Bridge
2000
70/100V/Ch.
1000x2
7.2
3.6
579
140/200V Bridge 2000
8 Ohms/Ch.
1250x2
13.7
6.8
1196
16 Ohms Bridge
2500
4 Ohms/Ch.
1500x2
16.2
8.1
1469
8 Ohms Bridge
3000
2 Ohms/Ch.
1500x2
19.2
9.6
1686
4 Ohms Bridge
3000
70/100V/Ch.
1500x2
13.7
6.8
1196
140/200V Bridge 3000
Watts
Thermal Dissipation
watts out
dissapated
Btu/hr
kcal/hr
0
40
137
34
313
266
907
229
381
316
1079
272
384
405
1384
349
313
266
907
229
835
360
1230
310
1010
459
1565
395
1024
662
2259
570
835
360
1230
310